Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации JVC, модель BR-HD50E

Производитель: JVC
Размер: 2.04 mb
Название файла: 6d7469f4-ef90-4b53-a9ca-1fdbf3f49f43.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Set it to OFF if the operation buttons are to be used. For REMOTE, select the buttons that can be operated with the LOCAL FUNCTION Menu. Editing cannot be controlled even after the REMOTE/LOCAL switch is set to REMOTE. To control with RS-422A, set REMOTE SEL 9P in the REMOTE [1/2] Menu screen to “ON”. Noise is produced on the playback • The tape is damaged. video. Replace the tape. Playback sound interrupted. • The head is dirty. Clean it with the specified head-cleaning tape. (XPage 9) Cannot play back. Is the setting for PB TAPE FORMAT in the SYSTEM [2/2] Menu screen something other than AUTO? Playback is not available when this menu item does not match the tape format. Time codes are not correctly recorded during DV signal input. Is TC DUPLI.: DV in the TC/UB/CLOCK [1/2] Menu screen correctly set up? Unable to turn on the power with the OPERATE button. Isn’t the REMOTE/LOCAL switch set to REMOTE when LOCAL FUNCTION in the REMOTE [1/2] Menu screen is not set to ALL KEYS? SERIAL REMOTE control does not function. Isn’t REMOTE SEL SER in the REMOTE [1/2] Menu screen set to OFF? For SERIAL REMOTE control, set it to ON or LOC+REM. Unable to operate BR-HD50 with the IEEE1394 terminal. • Isn’t REM SEL HDV/DV in the REMOTE [1/2] Menu screen set to OFF? To operate with the IEEE1394 terminal, set it to ON or LOC+REM. • When the controlling equipment (non-linear editor, etc.) does not recognize this unit, either reconnect the IEEE1394 cable, or reset the power to the unit. OTHERS Troubleshooting (continued) Symptom Action Cannot record HDV signals from the IEEE1394 terminal. • Is the IEEE1394 switch on the front panel set correctly? To record HDV signals, set this to HDV. • Is the HD signal format set correctly? Match the 60/50 SEL setting in the SYSTEM [2/2] Menu screen to the input HDV signal format. (XPage 40) Cannot record DV signals from the IEEE1394 terminal. Is the IEEE1394 switch on the front panel set correctly? To record DV signals, set this to DV. No HD signal is output from the HDMI OUT or COMPONENT OUT terminal. Is the HD signal format set correctly? Match the 60/50 SEL setting in the SYSTEM [2/2] Menu screen to the HD signal format. (XPage 40) HDMI OUT terminal video does not display on the monitor. Is the monitor compatible with video from the HDMI OUT terminal? Check the monitor specifications. To automatically set the HDMI OUT terminal video to the video format for the connected equipment (monitor), set MONITOR SELECT to HDMI[A] in the VIDEO Menu screen. No signal is output from the • Is the IEEE1394 switch on the front panel set correctly? IEEE1394 terminal during play-Match the IEEE1394 switch setting to the playback tape back. recording format. • When playing a tape recorded in HDV format, check that the HD signal format setting is correct. (XPage 40) OTHERS Checking the hour meter This unit displays the drum usage time as the hour meter in DRUM HOUR METER in the SYSTEM [2/ R button 2] Menu screen. Use it as a guide for regular maintenance. (XPage 8) Use standard DV cassette tapes or mini DV cassette tapes. MENU button SET button P button S button Operation • Set BR-HD50 to the STOP mode: 1. Press the MENU button to display the TOP Menu screen. 2. Press the R or P button to bring the cursor to SYSTEM. Press SET or the S button. • The SYSTEM [1/2] Menu screen is displayed. 3. Press the R or P button to bring the cursor to NEXT PAGE. Press SET or the S button. • The SYSTEM [2/2] Menu screen is displayed. • The drum usage time is displayed on DRUM HOUR METER in the SYSTEM [2/2] Menu screen. 4. Press the MENU button to return to the normal screen. TOP Menu screen –––MENU––– SYSTEM. . REMOTE . . AUDIO. . VIDEO. . TC/UB/CLOCK. . D I SPLAYSET . . EXI T SYSTEM [1/2] Menu screen –––SYSTEM[ 1 / 2 ] ––– STL/F.ADV :DV 2ND BACKUP REC : DV OFF LONG PAUSE T IME 30SEC REC LONG P.TIME5MIN LONG PAUSE MODE STBY-OFF “ , ” KEY FUNC. VAR/RECV REPEAT MODE OFF NEXT PAGE PAGE BACK SYSTEM [2/2] Menu screen –––SYSTEM[ 2 / 2 ] ––– DC I N MODE OPE OFF INDEX WRI TE INDEX OPERAT ION LOCK ON 60 / 50 SEL 60 FACTORY SETT I NG CANCEL DRUM HOUR METER 000200 PAGE BACK Drum usage time OTHERS Specifications • General Power requirements:DC 12 V W (from provided AC adapter) Power consumption:DC 12 V W 26.4 W 2.2 A Usable tape :Standard/ mini DV cassette tape Tape speed :18.8 mm/s Record/play time : 276 minutes (with LA-DV276PRO tape) 63 minutes (with M-DV63PROHD tape) External dimension:212 mm (W) . 88 mm (H) . 327 mm (D) (Excluding protruding parts) Weight :Approx. 3.9 d (Not including AC Adapter) Allowable operating temperature :5°C to 40°C Allowable storage temperature :–20°C to 60°C Allowable operating humidity :30% RH to 80% RH Allowable storage humidity :85% RH or less • Video Recording format :720/24p, 720/25p, 720/30p, 576/50p, 480/60p (BR-HD50U/HD50E), 480/60i (BR-HD50U), 576/50i (BR-HD50E) Video format : [HDV] Video signal recording format :HDV720p format, 8-bit, 19.7 Mbps Compression :MPEG-2 video (profile & level: MP@H-14) [...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории