Инструкция по эксплуатации Invacare, модель RLS6

Производитель: Invacare
Размер: 447.58 kb
Название файла: 1114832.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If any attachments are NOT properly in place, lower the patient back onto the stationary surface and correct this problem - otherwise, injury or damage may occur. 5. Activate the lift mechanism to raise the patient until they are completely supported by the lift. 6. Note the weight display. 7. When the weight display becomes stable press the LOCK button to lock the weight display. This will be indicated by the word .LOCK. appearing in the display window. NOTE: Should it be necessary to unlock the weight while the patient is still supported by the lift, the UNLOCK button may be pressed. The weight will unlock and the word .LOCK. will disappear from the display window. The weight value willthen be updated. Once the weight becomes stable the weight can be lockedagain by pressing the LOCK button. NOTE: Stable being defined as the weight fluctuating ± two.tenths of a pound. For example, a patient weighing one hundred pounds .the scale will fluctuate between 99.8 and 100.2 until the LOCK key is pressed. Fluctuation of the weight displayed is normal as noted above. Press the LOCK button to lock the weight. NOTE: The UNITS button may be pressed to toggle between units of pounds and kilograms. This is indicated by lbs or kg appearing in the display window. 8. The lift may now be lowered and the sling removed from the patient. Part No 1114832 5 Reliant Scale RLS6 NOTE: The patient.s weight will continue to be seen in the display window. NOTE: The display will turn off automatically after a two minute period of non.use [no changes in weight exceeding five pounds (two kilograms)]. You can not adjust the time delay for automatic shut off. NOTE: After the display has turned off, the weight may be recalled by pressing the ON/OFF button. NOTE: The unit can be turned off by pressing the ON/OFF button a second time. Replacing the Battery NOTE: For this procedure, refer to FIGURE 4. NOTE: The scale is powered by a nine volt alkaline battery that should provide approximately 1500 readings before needing replacement. When battery replacement is needed, LO BAT will appear on the display. Perform the following: 1. Slide the battery door open in the direction of the arrow. 2. Remove existing battery. 3. Install new battery. 4. Reinstall the battery door. Battery Door 9V Battery Assembled Scale Arrow FIGURE 4 Replacing the Battery Calibrate the Reliant Scale NOTE: For this procedure, refer to FIGURE 5 on page 7. NOTE: The Reliant Scale will be pre.calibrated at the factory with the load cell. Should it be necessary to re.calibrate the scale, follow the instructions outlined below. 1. The patient and the sling MUST be removed from the scale to properly calibrate the Reliant Scale. Refer to Operation in the Patient Lift Owner’s Manual for further instructions. 2. For sling detachment instructions, refer to Lifting the Patient in the Patient Lift Owner’s Manual. 3. Turn the scale display power on by pressing the ON/OFF key. 4. Rotate the Swivel Bar until the back of the scale display is visible. 5. Insert the tip of a paper clip or similar tool into the small hole on the back of the scale display and press the CAL button. NOTE: Once the CAL button is pressed, “CAL1” will be seen in the display window. 6. Press the UNITS key. The display reads CAL2. Reliant Scale RLS6 6 Part No 1114832 7. Press the LOCK/UNLOCK key. The display reads UNLD. 8. Press the ZERO key. The display reads LOAD. 9. Hang 200 pounds of calibrated weight from the scale and press the ZERO key. 10. Press the ZERO key. The display reads DONE. 11. Remove the weight. Press the LOCK/UNLOCK key. NOTE: The scale is now in test mode. 12. Press the ZERO key. The display reads 0.00 lb. NOTE: The scale will now be in normal operation. BACK VIEW OF THE SCALE DISPLAY CAL Button FRONT VIEW OF SCALE DISPLAY Display Window FIGURE 5 Calibrate the Reliant Scale Troubleshooting SYMPTOM PROBABLE CAUSE SOLUTIONS Unit does NOT work properly. Battery failure. Check battery. Replace if necessary. Battery has been replaced and unit still does NOT work properly. Contact Invacare for Service at 1-800-333-6900. Display Codes Calibration Required .Indicates improper stored calibration data, calibration is necessary. Over Capacity .Indicates a weight exceeding the capacity has been loaded on the scale. Part No 1114832 7 Reliant Scale RLS6 LIMITED WARRANTY PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the original purchaser/user of our products. This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state. Invacare warrants the products manufactured (excluding the 9V battery) to be free from defects in materials and workmanship for a period of one year from the date of purchase. If within such warranty period any such product shall be proven to be defective, such product shall be repaired or replaced, at Invacare’s option. ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории