Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Honeywell, модель W7340

Производитель: Honeywell
Размер: 630.92 kb
Название файла: c1ff1095-ced4-484f-99e7-b3e24b1a450b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The W7340 is used with both solid state temperature and humidity or enthalpy sensors. The W7345 is used with solid state temperature sensors only. FEATURES • Solid state control package provides accuracy, reliability and stability. • Housed in high-impact, glass-fiber reinforced plastic case. • Terminals included for connecting optional S963B1136Remote Potentiometer for remote minimum damper position control. • Communicates using a modified Modbus protocol. • Case matches the lines of the M7215 Damper Motor. • LED indicates the status of the device input. W7340 Only • Operates from the Modbus input, environmental sensors, and a DCV sensor to provide a totallyintegrated control system. • Combines minimum damper position potentiometerwith solid state temperature (10K NTC) and humidity orenthalpy changeover control to provide economizer free cooling function; this control can be overriddenby input via Modbus or DCV sensor. W7345 Only • Operates from the Modbus input and mixed/discharge air sensor to provide a temperature control system. • Combines the Modbus indoor and/or outdoor temperature input with the mixed air input to provideeconomizer dry bulb free cooling function. Contents Application.........................................................................1 Features ............................................................................1 Specifications ....................................................................2 Installation .........................................................................3 Wiring ................................................................................6 Operation...........................................................................7 Settings and Adjustment ...................................................7 Troubleshooting.................................................................11 63-2569—04 W7340, W7345 COMMUNICATING ECONOMIZER LOGIC MODULES W7340, W7345 COMMUNICATING ECONOMIZER LOGIC MODULES Models: W7340: Communicating Economizer Logic Module with minimum position potentiometer, setpoints for enthalpy or dry-bulb, and DCV. W7345: Communicating Economizer Logic Module with minimum position potentiometer and setpoint for dry-bulb temperature only. IMPORTANT W7340A, W7340B and W7345A: 1. Do not have the ability to set DCV minimum position for damper position for demand control ventilation. Damper may drive 100% open on call from CO2 sensor. 2. Do not have the E (enthalpy or dry bulb) curve setting. 3. W7340C has the ability to set DCV minimum position and has the E curve setting. Dimensions: See Fig. 1. Temperature Ratings: Operating Ambient: -40 to +149 °F (-40 to +65 °C). Shipping: -25 to +125 °F (-32 to +52 °C). Humidity Ratings: Noncondensing: 5 to 95% RH. Condensing: 100% RH. Inputs and Outputs: See Table 1. Electrical Ratings: Input Voltage: 24 Vac ±25%; 50/60 Hz (Class 2). Nominal Power Consumption (at 24 Vac, 60 Hz): 5 VA. Relay Contact Rating at 30 Vac (maximum power from class 2 input only): 1.5 A run, 7.5 A inrush. Patents: U.S. Patent 6,1,764. Other Patents Pending. Approvals: cUL listed. Underwriters Laboratories Inc. listed: Meets UL873 plenum requirements. Meets UL94-5VA plenum flammability requirements. FCC Part 15 Class B. CE. This product complies with Title 24 Part 6 CEC standard for Residential and Non-Residential Buildings - 2005, when installed according to instructions. 4-1/16 (103) 1-15/16 (49) 1-3/4 (44) 4-7/16 (112) 1-3/8 (35) 5/8 (16) M22813 Fig. 1. Dimensions of W7340 and W7345 in inches (mm). Accessories: 32005191-001 Sensor, 10K ohm with 2-1/4 in. (57 mm) probe. C7150B1046 Mixed Air Sensor, 10K ohm with mounting bracket. C7232 Carbon Dioxide Sensor for DCV. C7632 Carbon Dioxide Sensor for DCV. C7400A Solid State Enthalpy Sensor for use with W7340A and W7340B. C7400C Solid State Enthalpy Sensor for use with W7340C. C7600C Relative Humidity Sensor. S963B1136 Remote Potentiometer to provide remote control of damper minimum position. ST6008 Energy Management Timer for occupied/unoccupied control. ST7009 Electronic Programmable Timer for occupied/ unoccupied control. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitee, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 63-2569—04 2 W7340, W7345 COM...

Эта инструкция также подходит к моделям:
Вентиляторы - W7345 (630.92 kb)
Вентиляторы - W7340 (630.92 kb)
Вентиляторы - W7345 (630.92 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории