Войти:
Оценок - 5, средний балл: 5 ( )

Инструкция по эксплуатации Miele, модель DA 402

Производитель: Miele
Размер: 775.76 kb
Название файла: Da402usop.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


. . . . . . . . . . .410 W Overhead lighting . . . . . . . . . .3 x 20 W Voltage . . . . . . . . . . . . . . . . . . . . . 120 V Verify that the voltage, load and circuit rating information found on the data Frequency . . . . . . . . . . . . . . . . . . 60 Hz plate (located behind the grease Circuit rating. . . . . . . . . . . . . . . . . . 15 A filters), match the household electrical supply before installing the hood. If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. U 1-800-999-1360 V 1-800-565-6435 WARNING: THIS APPLIANCE MUST BE GROUNDED Appliance dimensions 1) and 2) Installation area Wall/ceiling area respectively for vent hole and outlet installation. Vent hole 5 7/8" (150 mm) with reducing collar 5" (125 mm). Appliance dimensions Do not install this exhaust hood over cooktops burning solid fuel. When installing the hood, make sure that the following minimum distance (S) between the top of a Miele cooking surface and the bottom of the hood is: -22" (55 cm) above electric cooktops -26" (65 cm) above gas cooktops -26" (65 cm) above an open grill For non-Miele cooking appliances maintain the safety distances recommended by the cooktop manufacturer in their installation and operating instructions. If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance. See "Important Safety Instructions" for further information. Standard unit height (H): DA 402 Air Extraction. . . . . . . . . . . .28 5/16- 40" . . . . . . . . . . . . . . . . . . (720 - 1015 mm) To fit the chimney, the distance between the top of the chimney and the ceiling must be at least 7/8" (20 mm). Cut out area in wall or ceiling for entrance of 6" (150 mm) ductwork or 5" (125 mm) ductwork with a reducing collar. 26" (65 cm) is recommended for all installations to allow for optimum work space under the hood. Read the entire installation procedure and determine height (S) before beginning the installation. Installations differ depending on the model and venting method. If the hood is fitted flush to the ceiling make sure that the remaining distance to the ceiling is not greater or less than appliance height (H). Installation Installation instructions See the enclosed installation instruction sheet. Please read the "Important Safety Instructions" and Installation instructions before installing this hood. Protective film The casing is covered with a protective film to prevent scratching during transport. Peel off the film before installing the casing parts. Dismantling If the hood needs to be disassembled, follow the instructions on the installation sheet in the reverse order. A lever is enclosed for easier removal of the chimney extension. ^After removing the screws from the chimney, slide the lever between the chimney and the chimney extension and gently apply pressure to ease the chimney from its hooks. Air extraction ,WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. The exhaust gases extracted by the hood should be vented outside of the building only. Do not terminate the exhaust ducts in attics, garages, crawlspaces, etc. To reduce the risk of fire, only use metal ductwork. Exhaust ducting and connections – The ducting should be as short and straight as possible, and the number of sharp bends should be minimized. – For efficient air extraction, the diameter of the ductwork should not be less than 6" (150 mm). Use of flat ducts also reduces the air extraction efficiency. – Noise levels of the hood will increase if flat ducts or round ducts of less than 6" (150 mm) in diameter are used. – Use smooth or flexible pipes made from approved non-flammable materials for exhaust ducting. – Where the ductwork is horizontal, it Please read and follow the must slope away from the hood at "IMPORTANT SAFETY least 1/8" per foot (1 cm per meter) to INSTRUCTIONS" to reduce the risk of prevent condensation from dripping personal injury. Follow all local building into the appliance. codes when installing the hood. – If the exhaust is ducted through an outside wall, a Miele Telescopic Wall Vent can be used. Air extraction If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue. Important! If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be insulated to reduce condensation. Condensate trap (optional accessory) In some cases, a condensate trap may also be required to collect and evaporate any condensation which may occur. This optional accessory is available ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории