The oil must be heated to at least 140° F prior to starting the wash cycle. (8) The wash frequency shall be once a day, not once a week, or once a month, no exception without a written release of warranty liability from end user. The wash control sequence shall be as follows: (a) Wash cycle is activated. (b) Oil temperature must meet 140° F before system shutdown. (c) Power supply and fan are shut down, fan coast time 60 seconds. (d) Quenchall + Exxon cleaner spray time 2 minutes. (e) Soak time 2 minutes. (f) Rinse time 2 minutes. (g) Dry time 10 minutes minimum. (h) Forced dry time 10 minutes. (i) If there is no forced dry time the fan shall be turned on first for a minimum of 5 minutes before power supplies are turned on. (9) Fire suppression system (by others) is recommended to customer as part of quote in writing to customer. If customer decides not to use fire suppression system, customer shall be aware of the risk factor involved and waive Trion from any fire liabilities in writing. (10) The PWM power supply shall be used for all ESP systems offered with close loop oil wash system, including Air Boss/Models12, 22 and 73 series. Furthermore, when multiple PWM power supplies are used for powering their outputs shall be connected to respective tier of cells, i.e., power outputs shall be in parallel and isolated from each other, so that their discharge energy is limited. The air flow rate shall be adjusted to achieve required efficiency at PWM power supply’s operation voltages. (11) System outline drawing, electrical schematics, field wiring, and piping diagram must be provided for all closed loop cleaning systems. All above operation parameters shall be described in appropriate system drawings. Warning such as “Warranty is void if system deviates from this design” shall be printed in bold letters on drawings. Customer must acknowledge and approve all outline drawings before the project is started. (12) Manual cleaning of the ionizer-collector cells is required every three months. The time can be extended only if proven not necessary by the actual installation. (13) Sample of machine tool fluid (oil) must be sent to Trion for evaluation prior to order acceptance. Special Considerations: (1) If metal fines are present in the airstream a mechanical pre-filtering system using high loft (low efficiency) polyester bag filters should be used. (2) In some cases, ambient (fugitive) capture systems can not use closed loop cleaning systems due to low inlet grain loading. Evaporation of the precipitated material causes a sticky, tenacious residue which will not wash off with the heated oil. References: American Tool, Saegertown Manufacturing, 20th Century, Louca Mold с c f Typical System Arrangement: > c c c EQUIPMENT SCHEDULE i \ft cast hoc y sima. i 1 /T SOHJUS BUTTERflY WUE. KEPHOC SEAL «fsa» Kuff wvt i \ft «owl set to op» a a {p.sxe.). c i mssM/MOM cace h i rasáis cace, o-ito (p.s.ic.) t i v? a*- 9°* wnmTat *ff cono?...
Эта инструкция также подходит к моделям:Вентиляторы - Air Boss 12 Series (276.69 kb)
Вентиляторы - 73 Series (276.69 kb)