Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Wolf Appliance Company, модель PWC482418R

Производитель: Wolf Appliance Company
Размер: 213.5 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Take a moment to read the warranty statement on page 19 and refer to it should service become necessary. CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com SAFETY INSTRUCTIONS AND PRECAUTIONS READ AND SAVE THESE INSTRUCTIONS Read this Use & Care Information carefully before using your new ventilation unit to reduce the risk of fire, electrical shock or injury to persons. To reduce the risk of fire, electric shock or injury to persons, observe the following: Use this unit only in the manner intended by Wolf Appliance Company. If you have questions, contact us at 800-332-9513. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel- burning equipment to prevent backdrafting. To reduce the risk of electric shock, this fan should only be used with fan speed control CM-18RT1 and CM-18RSTU2 (809403), manufactured by Trivar Laboratories, Inc. To reduce the risk of fire and to properly exhaust air, be certain to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages. Follow the heating equipment manufacturer’s guidelines and safety standards, such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities. To reduce the risk of fire or electric shock, do not use this hood with an additional speed control device. Ducted fans must always be vented to the outdoors. To reduce the risk of fire, use only metal ductwork. This unit must be grounded. For best capture of cooking impurities, the bottom of the hood should be a minimum of 30" (762) and a maximum of 36" (914) above the countertop. This product may have sharp edges. Be careful to avoid cuts and abrasions during installation and cleaning. Please read specification label on product for further information and requirements. SAFETY INSTRUCTIONS AND PRECAUTIONS READ AND SAVE THESE INSTRUCTIONS TO REDUCE THE RISK OF A COOKTOP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe). Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the size of the surface element. TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A GREASE FIRE, OBSERVE THE FOLLOWING: Smother flames with a close- fitting lid, baking sheet or other metal tray, then turn off the gas burner. Be careful to prevent burns. If the flames do not go out immediately, evacuate and call the fire department. Do not use water, including wet dishcloths or towels—a violent steam explosion will result. Never pick up a flaming pan— you may be burned. USE AN EXTINGUISHER ONLY IF: You know you have a Class ABC extinguisher and you already know how to operate it. The fire is small and contained in the area where it started. The fire department is being called. You can fight the fire with your back to an exit (NFPA Fire Safety Tips). For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc., off blower. Two installers are recommended because of the large size and weight of this hood. Your hood motor has a thermal overload that will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continually shuts off and restarts, contact a Wolf authorized service center. Avoid using food products that produce flames under the wall hood or island hood. Take care when using cleaning agents or detergents. Dimensions in parentheses are in millimeters unless otherwise specified. WOLF PRO VENTILATION HOOD FEATURES L...

Эта инструкция также подходит к моделям:
Вентиляторы - PW482210R (213.5 kb)
Вентиляторы - PW482210R (213.5 kb)
Вентиляторы - PW482718R (213.5 kb)
Вентиляторы - PW482718R (213.5 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории