Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Zephyr, модель AK8300ASX

Производитель: Zephyr
Размер: 400.88 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Do not ground to a gas pipe. Check with a qualified electrician if you are not sure the range hood is properly grounded. Do not have a fuse in the neutral or ground circuit. *National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575 This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product. AK8200AS - 710W, 5.95 Amps AK8300ASX (CBI-290B / CBI-600B) - 217W, 1.85 Amps / 460W, 3.85 Amps AK8300ASX (PBI-1100A / PBN-1000A/CBE-1000) - 780W, 6.55 Amps / 840W, 7.3 Amps A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary. FEDERAL COMMUNICATION COMMISSION INTERFACE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuantto Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does causeharmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help Important 3 List of Materials MODELS: AK8200AS AND AK8300ASX PARTS SUPPLIED AK8200AS AK8300ASX 1 - Power Pack 1 - Power Pack 2 - Baffle filters 3 - Baffle filters 2 - Halogen light bulbs (pre-installed) 4 - Halogen light bulbs (pre-installed) 1 - Dual internal blower (pre-installed) 1 - 8” round adapter 1 - 8” round adapter 1 - Remote blower wiring harness 1 - RF remote control (with battery) 1 - RF remote control (with battery) 1 - Hardware package 1 - Hardware package NO BLOWER HARDWARE PACKAGE CONTENTS Light Bulb Removal Suction Cup (1) M4 x 1” (4) M4 x 8 (4) Wire Caps (3) PARTS NOT SUPPLIED -Ducting, conduit and all installation tools -Cable connector (if required by local codes) -Single internal blower kit (CBI-290B, CBI-600B) - AK8300ASX only -Dual internal blower kit (PBI-1100A) - AK8300ASX only -External blower kit (CBE-1000) - AK8300ASX only - In-Line blower kit (PBN-1000A) - AK8300ASX only -Optional stainless steel hood liner (AK08xxAS) 4 Duct pieces Equivalent numberlength x used = Total Duct pieces Equivalent numberlength x used = Total 3-1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 6” Round wall cap with damper 30 Ft. x ( ) = Ft. 6” Round, straight 1 Ft. x ( ) = Ft. 6” Round, roof cap 30 Ft. x ( ) = Ft. 7”-10” Round, straight 1 Ft. x ( ) = Ft. 6” round to 3-1/ 4” x 10” rect. transition 1 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.900 elbow 15 Ft. x ( ) = Ft. 6” round to 3-1/ 4” x 10” rect. transition 900 elbow 16 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.450 elbow 9 Ft. x ( ) = Ft. 7” - 10” Round, 900 elbow 15 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.900 flat elbow 24 Ft. x ( ) = Ft. 7” - 10” Round, 450 elbow 9 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. wall cap with damper 30 Ft. x ( ) = Ft. Round wall capwith damper 7” - 10” 30 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.to 6” round transition 5 Ft. x ( ) = Ft. 7” - 10” Round, roof cap 30 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect.to 6” round transition 900 elbow 20 Ft. x ( ) = Ft. 7” round to 3 1/ 4” x 10” rect. transition 8 Ft. x ( ) = Ft. 7” round to 3-1/ 4” x 10” rect. transition 900 elbow 23 Ft. x ( ) = Ft. 6” Round, 900 elbow 15 Ft. x ( ) = Ft. 6” Round, 450 elbow 9 Ft. x ( ) = Ft. Subtotal column 2 = Subtotal column 1 = Total ductwork = Ft. Ft. Subtotal column 1 = Ft. Ft. Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. Installation Ducting 5 Installation – Mounting Height & ClearanceMin 26" - Max 36" 36" DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air flow efficiency for single blower and 8” round duct for dual and remote blowers. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use calculation (on page 5) to compute total available duct run when using elbows, transitions and caps. ALWAYS, when possible, reduce the number or transitions and turns. If...

Эта инструкция также подходит к моделям:
Вентиляторы - AK8200AS (400.88 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории