Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации John Lewis, модель JLBIHD904

Производитель: John Lewis
Размер: 270.64 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Unpacking Before unpacking the cooker hood position the carton with the arrows pointing upwards as illustrated on the carton. The cooker hood is made up of the following components: Ref Qty Product Components 1 1Canopy complete with:Controls, Lighting, Fan Assembly, Grease Filter,Charcoal Filter. 2 1Telescopic Chimney comprising: 2.1 1 Upper ChimneyStack 2.2 1 Lower ChimneyStack 8a 1Right-Hand Recirculation grille 8b 1 Left-Hand Recirculation grille 9 1 o150-120 Ducting Spigot 10 1 o120-125 Ductingflange 14 1 Ducting Extension Pipe 14.1 2Recirculation Outlet Extentions 15 1Recirculation Outlet Adapter Ref Qty Installation Components 7.2.1 2 Upper chimneywall fixing brackets 12c 6 Chimneyfixing screws Ref Qty Documentation 1 Instruction booklet . Installing the Cooker Hood Fitting the Wall Brackets • Draw a vertical line on the supportingwall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. • Draw a horizontal line at 650 mm above the hob. • Place bracket item 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch)with the vertical reference line. • Mark the wall at the centres of the holes in the bracket. • Place bracket item 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch)with the vertical line. • Mark the wall at the centres of the holes in the bracket. • Draw a horizontal line through the vertical at 306mm above the hob and mark two hole centres at 116mm either side of the vetical line. • Drill o8 mm holes at all the centre points marked. • Insert the wall plugs (not supplied) in the holes. •Fix the brackets using the screws (not supplied). • Insert two screws into the two holes 116mm either side of the vertical line and tighten leaving a space between the underside of the screwhead and the wall of5-6mm. Note: If the hood is to be installed onto a hollow construction or plaster or partition board wall then special fixing screws will be required (not supplied). Fitting the Canopy Hood • Before starting to fix the hood body, tighten the two screws item Vr located on the top of the hood body. • Hook the hood body onto the two screws item 12a. •Fully tighten the screws item 12a. • Using a screw driver and spirit level, adjust the screws item Vr until the hood body is level. Extraction (Ducted) The cooker hood is more effective when installed in the extraction mode (ducted to the outside). Venting kits may be purchased through your retailer or DIY store, and must be evacuated through an outside vent of o125 (5ins) or o150mm (6ins). The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102-B1. When the cooker hood is ducted to the outside the charcoal filter must be removed. Fitting the Ducting • Fit the o150mm (6ins) ducting to the spigot on top of the hood body as illustrated. • When using o125mm (5ins) ductingfit item 9 and 10 on to the spigot on the top of the hood body as illustrated. • For the best performance use the shortest possible run of ducting and we recommend the use of rigid pipe in preference to flexible hose as this will improve the flow of air while reducing turbulence,which causes noise and a loss ofperformance. • If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler, then its flue must be be of the room sealed or balanced flue type. • If other types offlue or appliances are fitted ensure that there is an adequate supply of air to the room. • The cooker ductingwhen fitted in the extraction mode must never be connected to central heatingflues, radiators or water heaters. Recirculation Mode The cooker hood is supplied specified for use in the recircula tion mode,with the charcoal filter fitted. In the recirculation mode contaminated air is passed through the charcoal filter to be purified and recirculated into the kitchen through the grille outlets on either side of the chimney. • Assemble the two halves of the ducting extension pipe item 14. • Push-fit the extension pipe on to the ducting spigot on top of the canopy. • Push-fit the recirculation adapter item 15 on to extension pipe item 14. • Insert the recirculation outlet extensions item 14.4 into the recirculation adapter item 15. • The recircualtion grilles item 8a and 8b must be fitted after the lower chimney item 2.2 has been fitted. • Ensure the activated charcoal filter has been fitted. . . . . Fitting the Upper Chimney • Expand the sides of the upper chimney stack item 2.1 and place the chimney over the two brackets 7.2.1 ensuring they are well seated. • Secure the chimney stack to the brackets 7.2.1 using the four self tapping screws item 12c (2.9 x 9.5mm) supplied. Fitting the Lower Chimney • Expand the of the lower chimney stack item 2.2 and place the chimney over the upper chimney stack item 2.1 an...

Эта инструкция также подходит к моделям:
Вентиляторы - JLBIHD603 (270.64 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории