Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Emerson, модель CF2800PW

Производитель: Emerson
Размер: 334.84 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 19). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 18). Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. WARNING ! NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY. Figure 19 ASSEMBLY WARNING ! To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket. How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. WARNING ! Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors supplied. (Figure 20.) BLACK LISTED WIRE CONNECTOR (3) WHITE SUPPLY SUPPLY (HOT) (NEUTRAL) BLUE FAN WIRE WHITE BLACK FAN FAN WIRE WIRE SUPPLY GROUND WIRE HANGER GREEN WIRE BRACKET (GROUND) FROMHANGER BALL THREADED GREEN WIRE (GROUND) STUD (2) FROM HANGER BRACKET Figure 20 2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 20). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 20). After connections have been made, separate the white and green leads from the black and blue leads. Carefully turn the leads upward and push the green and white leads into one side of the outlet box. Then push the black and blue leads into OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD 8 the other side of the outlet box. WARNING ! Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result. 3. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 20). 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 20). 5. Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied). (Figure 21.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch. CEILING COVER LOCKWASHERS (2) KNURLED KNOBS (2) 1-1/4" THREADED STUDS (2) Figure 21 WARNING ! To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling. 6. Screw three candelabra base lamps (60-watt each max.) in the light fixture sockets. Pass the light fixture switch chain through the light fixture glass (Figure 22). Position the glass on the light fixture so that the three elongated points of the glass are over the three lamps. Install the fiber washer and the finial nut (supplied) to hold the glass on the light fixture. Securely tighten the finial nut. 7. Slip the speed control switch pull chain through the hole in the oval pendant (supplied), then secure the pendant by snapping the plastic coupling (supplied) onto the end of the chain (Figure 22). Repeat this procedure to connect the pendant to the light switch pull chain. FIBER WASHER FINIAL NUT LIGHT FIXTURE PENDANT PLASTIC COUPLING GLASS SPEED CONTROL PENDANT PLASTIC COUPLING LIGHT FIXURE SOCKET (3) 60-WATT CANDELABRA BASE LAMP (3) Figure 22 Using Your Ceiling Fan 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the 4-position speed control switch pull chain. The operating sequence is as follows: THREE-SPEED 1st Pull—HIGH 3rd Pull—Low 2nd Pull—Medium 4th Pull—OFF 3. If airflow is desired in opposite direction, turn your fan off and wait for the blades to stop turning, then press the rocker switch located on top of the motor housing, and turn the fan on again (Figure 23). The fan blades will turn in the opposite direction and reverse airflow. 4. Check the operation of the light fixture by gently pulling the light switch pull chain. LIGHT SWITCH PULL CHAIN SPEED CONTROL SWITCH PULL CHAIN REVERSING SWITCH TOP OF HOUSING Figure 23 9 Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleanin...

Эта инструкция также подходит к моделям:
Вентиляторы - CF2800BS (334.84 kb)
Вентиляторы - CF2800WB (334.84 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории