Войти:
Оценок - 3, средний балл: 3 ( )

Инструкция по эксплуатации Emerson, модель CF2455PW00

Производитель: Emerson
Размер: 277.5 kb
Название файла: 2a63abca-09e0-48a6-9fc8-ac5483253576.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


A loose setscrew could create fan wobble. CEILING COVER SETSCREW PIN HANGER BALL DOWNROD Figure 4 11. The blue, black, white, and yellow leads exiting the downrod are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above the ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads. 5 6 12. Position the center styrofoam section on the upper section, and then position the fan motor and housing on the center section so that the bottom of the motor is facing you (Figure 5). The styrofoam sections will hold the assembly while you perform the following steps. 13.Using the 3/16” setscrew wrench (supplied), loosen the setscrew in the collar of the light kit adapter assembly (Figure 6). 14.Pass the connectors and wires from the motor shaft through the light kit adapter collar (Figure 7) in the following sequence: CENTER STYROFOAM SECTION FAN MOTOR AND HOUSING ASSEMBLY UPPER STYROFOAM SECTION Figure 5 a. First, pass the four-pin connector through the collar; b. Next, pass the single-pin connector through the collar; c. Then pass the white and blue wires through the collar. 15.Screw the light kit adapter tightly onto the motor shaft (Figure 6), then tighten the setscrew in the collar. 16.Securely connect the jumper assembly (supplied) connectors to the four-pin connector and the onepin connector from the motor shaft (Figure 7). 17. Securely connect the black wire from the light kit plate assembly to the blue wire from the motor shaft using a wire connector (supplied) (Figure 7). Connect the white wire from the plate assembly to the white wire from the motor shaft using a wire connector (supplied). SINGLE-PIN CONNECTOR SETSCREW COLLAR FOUR-PIN CONNECTOR LIGHT KIT ADAPTER Figure 6 18. Secure the light kit plate assembly to the light kit adapter by threading three 8-32 x 3/8” phillips head screws (supplied) into the threaded holes in the adapter assembly. (Figure 8). NOTE: Do not pinch wires between the light kit plate assembly and the adapter assembly. 19. Lift the fan assembly from the styrofoam and remove the center styrofoam section. Turn the fan assembly over and carefully position it on the upper styrofoam section so that the hanger ball/downrod assembly is at the top (Figure 9). LIGHT KIT ADAPTER LIGHT KIT PLATE ASSEMBLY BLUE WIRE BLACK WIRE WHITE WIRES JUMPER ASSEMBLY Figure 7 8-32 x 3/8" PHILLIPS HEAD SCREW (3) LIGHT KIT ADAPTER LIGHT KIT PLATE ASSEMBLY Figure 8 UPPER STYROFOAM SECTION FAN MOTOR AND HOUSING ASSEMBLY Figure 9 20. Position one fan blade on the flange assembly and secure by installing the left and right blade holder caps using two 10-32 x 3/8” pan head screws (supplied) for each holder cap (Figure 10). Install the remaining four fan blades using the same procedure. 10-32 X 3/8" PAN HEAD SCREW (2 PER HOLDER CAP) LEFT BLADE HOLDER CAP FLANGE ASSEMBLY RIGHT BLADE HOLDER CAP Figure 10 21. You have now completed the initial assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan. How to Hang Your Ceiling Fan WARNING ! The fan must be hung with at least 7' of clearance from floor to blades (Figure 11). WARNING ! To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt. WARNING ! Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall. OUTLET BOX TWO SCREWS SUPPLIED WITH TAB OUTLET BOX HANGER BRACKET Figure 12 2. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 13). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 12). WARNING ! Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. CEILING FLOOR AT LEAST 7' Figure 11 NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY. OUTLET WARNING ! HANGER The outlet box and joist must be securely mounted BRACKET and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”. 1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 12.) BOX HANGER BALL/ DOWNROD ASSEMBLY Figure 13 WARNING ! To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and the hanger bracket. 7 How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. WARNING ! Turning off wall switch is not sufficient. To avoid possible electrical shock,...

Эта инструкция также подходит к моделям:
Вентиляторы - CF2455ORB00 (277.5 kb)
Вентиляторы - CF2455BS00 (277.5 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории