FV-11VH2 FV-11VHL2 back cover back cover The Panasonic ceiling mount ventilating fans uses a sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal cut-off for safety. The grille covering the main body is a spring-loaded, quick-release type. A damper for preventing counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The heater for this unit is a 1400 W sheathed heater. A thermostat and thermal cut-off switch have been added for safety in case of an abnormal temperature rise in the heater. The lighting unit is an energy-saving, lighting device which uses two 18 W fluorescent lamps and produces almost the same illumination as a standard 100 W incandescent lamp (FV-11VHL2). UNPACKING SUPPLIED ACCESSORIES DESCRIPTION Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. FOR MODEL FV-11VH2 FOR MODEL FV-11VH2 POURLE MODELE FV-11VHL2 POURLE MODELE FV-11VHL2 Ventilating unit DIMENSIONS 2 1/8 (54.8) 14 (357.8) 18 1/8 (460) 2 1/2 (62) 11 7/8 (301) 13 1/4 (337.8) 7 5/8 (195) 5 (128.7) 11 1/4 (285.5) 18 1/8 (460) 7 3/4 (196) 1 (25) 16 (407) 19 1/2 (497) 19 1/2 (497) 16 (407) 11 1/4 (285.5) 5 (128.7) 7 3/4 (196) 7 5/8 (195) 2 1/2 (62) 11 7/8 (301) 1540 3. This product must be properly grounded. Noise Vent (sone) 0.6 0.7 Only for FV-11VHL2. AC 120V, 60Hz. SPECIFICATIONS GENERAL SAFETY INFORMATION 650 720 29.5 Exhaust & Circulation 10. This product (FV-11VHL2) has a fluorescent lamp that contains mercury. Disposal may be regulated in your community due to environmental considerations. For disposal or recycling information, please contact your local authorities or the Electronics Industries Alliance:Vent (0.1" WG) (cfm) 8. Make sure that all duct work is properly vented. 9. DO NOT INSTALL THIS UNIT OVER A BATHTUB OR SHOWER ENCLOSURE. 15.6 (7.1) 17.8 (8.1) GENERAL SAFETY INFORMATION CONTINUED WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact the manufacturer. B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Neither unauthorized modification, repair nor disassembly is allowed. C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel buming equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. E. Ducted fans must always be vented to the outdoors. F. Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce the risk of fire or electric shock, do not use this unit with any solid-state control device. G. Before servicing or cleaning unit, switch power off at service panel and lock panel cabinet to prevent power from being switched on accidentally. If the panel cabinet cannot be locked, securely fasten a clearly visible warning label to the service panel. H. Never place a switch where it can be reached from a tub or shower. I. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only.) J. Use only on 20 ampere branch circuit. WIRING DIAGRAM Circulating fan unit Red White Black Motor(C) White Thermal cut-off o o(230 F (110 C)) Heater (1400W) Thermostat o o(140 F (60C)) Fuse (20A) Ventilating fan unit Red White BlackMotor(V) Capacitor BlackWhiteWhiteBlack Junction box Green Earth ground Power Supply AC120V 60Hz Switch( notincluded) Switch( notincluded) PCB ONOFFONOFF Black Power Supply AC120V 60Hz Circulating fan unit Motor(C) Earth ground Junction box Motor(V) Ventilating fan unit ONOFFONOFFOFF ONONOFF PCBRed White Black White Black Fuse (20A) Thermal cut-off o o(230 F (110 C)) Heater (1400W) Thermostat o o(140 F (60 C)) Lighting unit Fluorescent lamp Electronic ballast WhiteBlack Fuse( 3.15A) Red White Black Capacitor Night lampBlackWhiteBlack WhiteBlack BlackWhite Green Switch(notincluded) Power Supply AC120V 60Hz Power Supply AC120V 60Hz Power Supply AC120V 60Hz Switch(notincluded) Switch(notincluded) Fig.2-2 Fig.2-1 (Fig.3) Fig.2-3 Illustrations in this manual common use the image of FV-11VHL2, and mark for FV-11VHL2 only, others are same for FV-11VH2. INSTALLATION (JOIST MOUNTING- ) Fig.3 Fan body Suspension bracket Suspension bracket Suspension bracket Suspension bracket Fan body Suspension ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории