Remote switch is on • Adjust remote switch to desired position. Thermostat Fan switch is in On position • Normal operation. HVAC system is running to satisfy heating or cooling requirements. • Normal operation. Ventilation limit is set to 100% ventilation limit. • Set ventilation limit to 60%. The control may not be able to meet the recommended ventilation requirements. • Increase ventilation airflow through fresh air duct and adjust settings. Low ventilation air flow. • See Problem: Not enough airflow. • Damper does not open during checkout or • Damper does not close. Incorrectly wired. • Check wiring connections per appropriate wiring diagram. Transformer output. • Verify 24 Vac applied to actuator. Damper actuator motor failure or mechanical failure. • Manually open damper and verify free movement; damper should return to closed position when no power is applied. • If damper moves freely but does not operate when 24 volts is applied, replace damper actuator. • If damper does not move freely, replace fresh air damper. Cooling compressor comes on when there is no cooling call from the thermostat. Incorrectly wired. • Check wiring connections per appropriate system diagram. • An isolation relay may be required when appliances are connected to the GT terminals on the ventilation control. (For an example, see wiring a fan for a steam humidifier diagram.) Not enough airflow Obstruction or duct size • Check for obstructions in the fresh air duct and weather hood. • Check for kinks in ductwork. • Make sure all manual dampers are fully open. • Make sure the stops on the EARD damper allow it to open fully. • Increase duct size. • Add a booster fan to the fresh air duct. NOTE: After any changes to the ductwork, repeat the Measuring Airflow section. 9 68-0282—07 Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL 68-0282—07 10 WIRING DIAGRAMS Consult thermostat Installation Instructions for alternate terminal designations. Fig. 1. Single transformer, conventional system. Fig. 2. Dual transformer, conventional system. Fig. 3. Multi-stage conventional system. Fig. 4. Wiring heat pump without emergency heat. Wake Room System Fan Heat Auto AM DST Tue R C W Y G R RC W Y G M19994A GF RC CC CH W GT W8150A HVAC Wake Room System Fan Heat Auto AM DST Tue W R HVAC HEATING COOLING R C C Y G R RC W Y G M19995A GF RC CC CH W GT NOTE: REMOVE FACTORY INSTALLED JUMPER BETWEEN CC AND CH ON W8150. W8150A Wake Room System Fan Heat Auto AM DST Tue R C W1 W2 Y1 Y2 G R RC C W1 W2 Y1 Y2 G M19996 GF RC CC CH W GT HVAC W8150A Wake Room System Fan Heat Auto AM DST Tue R C Y G O R RC W Y G O/B M19997A GF RC CC CH W GT HVAC W8150A Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL 11 68-0282—07 Fig. 5. Wiring heat pump with emergency heat. Fig. 6. Wiring with a PC8900. Fig. 7. Using a remote switch or timer. Fig. 8. Wiring to an HRV/ERV. Fig. 9. Wiring an exhaust fan. Wake Room System Fan Heat Auto AM DST Tue R C Y W2 E G O R C W1 Y1 W2 E G O/B M19998A GF RC CC CH W GT HVAC W8150A M19999 W8900 REMOTE AUX DAMPER C R XFMR RH RC HUM HUM VNT VNT ® AT120 W8150A EARD-6 NOTE: CONFIGURE PC8900 SO ALL VENT PROGRAM SETTINGS ARE OFF; THE VENT BUTTON ON THE PC8900 THEN SERVES AS A REMOTE AND THE W8150 CONTROLS BACKGROUND VENTILATION. Ventilation Control Ventilation Control Service Auto Continuous Off (Remote Only) M22000 EARD-6 FAN TIMER REMOTE AUX DAMPER C R XFMR AT120 W8150A Ventilation Control Ventilation Control Service Auto Continuous Off (Remote Only) M22001 HR150/ER150 EARD DAMPER NOT USED WITH HRV/ERV. REMOTE AUX DAMPER C R XFMR RED BLACK AT120 W8150A 1 1 FAN TIMER NOTES: – BALANCE THE HRV/ERV TO 160 CFM OR LOWER. – SET VENTILATOR SPEED KNOB TO 0. Ventilation Control Ventilation Control Service Auto Continuous Off (Remote Only) M22002 EXHAUST FAN 120 VAC AT120 AT120 R8222 W8150A REMOTE AUX DAMPER C R BLUE BLUE RED BLACK XFMR EARD-6 FAN TIMER 120 VAC L1 L2 Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL •100 cfm. CONVERSION TABLE R C W1W2Y1Y2G FAN W8150A GF RC HE440 CC CH W GT R8222 WakeRoomSystemFanHeatAutoDSTTueAM M22021A Fig. 10. Wiring fan for a steam humidifier. BLACKBLUEBLUERED RRCCW1W2Y1Y2G Area Airflow sq ft sq m cfm lps 1000 93 40 19 1300 121 50 24 1600 149 60 28 1900 177 70 33 2200 204 80 38 2500 232 90 42 2800 260 100 47 3100 288 110 52 3400 316 120 57 3700 344 130 61 4000 372 140 66 4300 399 150 71 4600 427 160 76 Multi-System Setup Example Total square feet and bedrooms should be proportionately split between the ventilation controls based on sq ft served by each system regardless of where the bedrooms are located. Example: 5,000 sq ft, six bedrooms: System 1: • serves 3200 sq ft, • two bedrooms. • fresh air intake measured at 127 cfm. System 2: • serves 1800 sq ft, • four bedrooms • fresh air intake measured at 98 cfm. Set W8150 for System 1: • 3100 sq ft, • four bedrooms • 130 cfm. Set W8150 for Syst...

Эта инструкция также подходит к моделям:
Вентиляторы - W8150 (1.07 mb)
Вентиляторы - W8150 (1.07 mb)
Вентиляторы - Y8150 (1.07 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории