|
Фрагмент инструкции
(See page 9 for optional ducting accessories). • Check that the mains voltage matches with the voltage on the data plate inside the canopy rangehood. • Check that the installation complies with standards of local gas and electricity authorities. • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent of similarly qualified person in order to avoid a hazard. Safety warnings – For the installer When installing the cooker hood, make sure you adhere to the minimum and maximum distances from the cooker hood base to the hob surface (as per table on right page 5). Exhaust duct installation: The following rules must be strictly followed to obtain optimal air extraction. • Keep exhaust duct short and straight • Do not reduce the size or restrict exhaust duct. • Keep bends in the exhaust duct to a minimum. • When using flexible duct always install duct with helix pulled taut to minimise pressure loss. • Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the cooker hood. Exhaust air must not be discharged into a wall cavity, unless the cavity is designed for that purpose. The exhaust from the cooker hood must not be discharged into any heating flue, which may carry combustion products from other sources. ERCM9010AS ERCE9020AS 100mm500mm391mmO163mm* 900mm1175mm(maximum) 328mm593mm 100mm500mm391mmO163mm* 900mm1175mm(maximum) 328mm593mm ERCG9030AS 83mm520mm407mmO163mm900mm1275mm(maximum) 331mm698mm Installation sequence 1. Using a spirit level mark a vertical centre line on the wall where the hood is to be positioned, and a horizontal line at the hood base position (refer diagram bottom left). NOTE: The height of the underside of the hood body must be a minimum of 600mm above an electric cooktop & 650mm above a gas cook top and a maximum height of 800mm (see table right). Distance from hood base to top of hob hob type minimum* maximum gas 650mm 800mm electric 600mm 800mm * If the instructions of the hob specify a greater distance than the minimum above, then that shall be the minimum height for installation 2. Mark the location for the wall and ceiling bracket fixing points above the hood base using the hood base as the reference point (refer diagram left). 3. Install wall and ceiling mounting brackets with suitable screws (to support a total weight of 30kg) to the wall at the positions marked in diagram left. 4. Remove the protective plastic film from the hood body and hang hood on the mounting brackets then secure at the anti-tilt locations as indicated in diagram left. Depending on the preferred installation/ducting mode, follow step 5a or 5b below. 5a. Recirculating mode (Fig. a). Using the centre line, secure the ceiling mount bracket to the wall using suitable screws. Attach the recirculating T-piece (optional kit AR600RK for models ERCM9010 and ERCE9020, or AR600RKG for model ERCG9030) to the ceiling mount bracket. Install flexible pipe between T-piec...
Эта инструкция также подходит к моделям:Вентиляторы - ERCE9020AS (2.69 mb)
Вентиляторы - ERCE9020AS (2.69 mb)
Вентиляторы - ERCE9020AS (2.69 mb)
Вентиляторы - ERCG9030AS (2.69 mb)