Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Sirius Range Hoods, модель SU900

Производитель: Sirius Range Hoods
Размер: 1.04 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The ducting connection to the hood must be in line with the central vertical axis of the range hood 1” away from the back wall on which the hood is to be mounted. Range hoods may interrupt the proper flow of combustion gases from fireplaces, gas furnaces and gas water heaters. To minimize the risk of drawing these lethal gases back into the home, please follow the heating equipment manufacturers safety standards and guidelines carefully. Refer to NFPA and ASHRAE for additional information. E L E C T R I C A L WARNING: All electrical work must be performed by a qualified electrician. Please ensure that the appropriate electrical codes or prevailing local building codes and ordinances are adhered to. Ensure that the electricity supply is disconnected at source. Do not use an extension cord or adapter plug with this appliance. This appliance must be grounded. Connect to a properly grounded branch circuit, protected by a 15 amp circuit breaker. Electrical Supply This range hood requires a 120V, 60Hz supply and draws a maximum of 3 amps. The electrical supply to the range hood should be at least 17” from the underside of the installed range hood. For a typical installation, where the underside of the range hood will be 30” above the counter top and the counter top is 36” above the floor level, the electrical supply should be 76” above floor level and no further than 3” to the right (as you face the wall) of the central axis of the range hood. 2 I N S T A L L A T I O N I N S T A L L A T I O N Applications The SUT900 can either be installed inside a wall cabinet (provided the inside depth is greater than 11”) or used in a custom designed wooden hood. Where installed directly into a wall cabinet, there are two options: Directly into the cabinet without any form of hood. Directly into the cabinet together with Sch31A where the Sch31A acts as a liner hood and is attached to either the underside of the cabinet or into the sides of the cabinets alongside. Depending on which model is used, prepare a cut-out in the underside of the wooden hood to allow the SUT900 to fit up into the hood (refer to figure 3 or 4). If Sch31A is being used, it can be held up under the cabinet and used as a template. Remember to make the depth 10.3”. 19.4”20.5” Figure 3 For the 20.5” model, the cut out should 19.4” x 10.3”. 26.5””27.6” Figure 4 For the 27.6” model, the cut out should be 26.5” x 10.3”. Please ensure that the SUT900 is installed as far forward in the wooden hood as possible and centered over the cooking area. Sch 31A If Sch31A is to be used for under cabinet application, it should be installed now. Screw Sch 31A to the 4 hole locations. Make sure it lines up with the cut out in your cabinet (refer to figure 5). Figure 5 The SUT900 has pressure springs on the front and back that will “hook” onto the top surface of the underside of the hood when it is pushed up into the hole that has been cut out (refer to figure 6) Figure 6 3 There are four holes on the inside of the SUT900 to fix the unit into the edge of the base of the wooden hood (refer to figure 7). Figure 7 Connecting Electricity and Ducting Please refer to the Electrical Supply section on page 2 for the required location of the electrical supply. CAUTION: Make sure the power is turned off at source. Make electrical connections (refer to Figure 8). Ensure that the plastic flaps at the exhaust outlet for the fan move freely and have not become jammed or stuck. Figure 8 Connect the appropriate length of ducting to the fan exhaust point and join up with the ducting to the exterior. Do not fix the ducting to the range hood exhaust outlet with screws use duct tape. Use duct tape on all joints. Re-Circulating Requirements If the unit is to be used in the re-circulating mode, fit the carbon filters after the installation is complete (refer to Figure 9). Figure 9 The carbon filter fits in behind the aluminium grease filter. Ensure that the plastic tabs on the carbon filter are facing outwards otherwise it will be difficult to remove it later for replacement. A short length of ductwork must be connected from the exhaust outlet on the fan to wherever the air is to be exhausted. Allow sufficient space to connect the ductwork to the top of the exhaust outlet on the fan housing. Do not fix the ducting to the range hood exhaust outlet with screws, use duct tape. Duct tape should be used on all joints. 4 O P E R A T I N G P R O C E D U R E S O P E R A T I N G P R O C E D U R E S Read all the instructions before operating the appliance. Save these instructions for future reference. General Advice Ensure that the grease filters are in place. Without these components, operating blowers could catch on to hair, fingers and loose clothing. Keep fan, filters and surfaces clean of grease and fat. Always turn hood fan ON when cooking. NEVER leave cooking unattended. NEVER dispose cigarette ashes, ignitable substances or any foreign objects into blowers. Cooking that generates flame is not recomme...

Эта инструкция также подходит к моделям:
Вентиляторы - SCH31A (1.04 mb)
Вентиляторы - SUT900 (1.04 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории