Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Hotpoint, модель HX901X

Производитель: Hotpoint
Размер: 1.74 mb
Название файла: 56216a98-d4ff-4c7a-a473-3068a319d36c.pdf

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


Then connect it to the steam and odour exhaust duct by means of a pipe of a suitable diameter. INSTALLATION CHIMNEY DUCT ASSEMBLY • Take the two chimney ducts A and B (Fig.5) and rest the lower part of duct A on top of the hood. • Fasten duct A to the hood using screws K (Fig.3), provided. • Raise the mobile part B until it reaches the ceiling, making sure it is perpendicular with the hood. • Fasten it with the screws M (Fig.5), provided. Fig.4 Fig.5 GB 6 INSTALLATION Electrical Connection • The hood is intended for a fixed permanent installation. For the mains voltage and frequency information, consult the rating plate situated inside the hood. The power supply cable (type H05VV-F 3x0.75mm2) connected to the hoods terminals marked ‘L’ (mains), ‘N’ (neutral) and fastened by means of the cable clamp. It must be connected to a suitable and accessible fixed power point by qualified personnel following all laws in force, providing for an omnipolar switch above the electrical connection with a minimum contact opening of 3mm. • The manufacturer declines all responsibility for injury or damage resulting from incorrect installation and use. GB 7 GETTING TO KNOW YOUR COOKER HOOD The Controls WARNING: Children should not be allowed to play with the appliance or tamper with the controls. Key 1 Switches the extractor motor on/off. Key 2 Reduces the operating speed. Key 3 Increases the operating speed. Key 4 Will turn the motor off automatically after 12 minutes - When this function is enabled a appears in the display A (bottom, right hand side). Key 5 Switches the light on and off. Key A Display. GB 8 CARE AND CLEANING Before cleaning your cooker hood or carry out any maintenance, switch the omnipolar switch to OFF to disconnect the hood from the electricity supply. CLEANING METAL GREASE FILTERS The filters must be cleaned every 2 months of operation, or more frequently with heavy usage, and can be washed in a dishwasher. • Remove the filters one at a time by pushing them towards the back and pulling down at the same time. • Wash the filters, taking care not to bend them. Allow them to dry thoroughly before refitting. • When refitting the filters, make sure that the handle is visible on the outside. NOTE: After every 30 hours of use, the microprocessor which is the heart of the system, indicates with a flashing letter ‘A’ on the display that the metal grease filters should be cleaned. Cleaning the filters reduces the fire risk and improves the performance and efficiency of your cooker hood. Clean the metal grease filters, following instructions in the ‘Care and Cleaning’ section. After cleaning cancel the warning message as follows: • Switch off the hood. • Press and hold Key 2 for more than 5 seconds. When the key is pressed the letter ‘A’ will appear on the display, after the 5 seconds the letter disappears and the microprocessor starts a new 30 hour count down to the next warning message. GB 9 CARE AND CLEANING REPLACING THE ACTIVATED CARBON FILTER (RECIRCULATION VERSION) The filter is not washable and must be replaced (see NOTE below). • Remove the metal grease filters. • Remove the saturated activated carbon filters ‘O’ Fig. 15, by turning them clockwise and then removing them from the guide pegs on the outdoor venting assembly. • Dispose of the carbon filters. • Fit the new filters making sure that the holes fit well around the guide pegs of the outdoor venting assembly. Turn them anti-clockwise until you hear them click into position. • Replace the metal grease filters. NOTE: If the hood is used in the recirculation version with carbon filters to purify exhaust fumes, the microprocessor which is the heart of the system, must first be ‘informed’ that it is managing a cooker hood in recirculation mode. To do this: • Switch off the hood. • Press and hold Key 4 for more than 5 seconds. When the key is pressed ‘-’ will appear on the display (indicating that the hood is not using the carbon filter). After the 5 seconds this becomes a ‘C’ on the display (indicating that the hood is using the carbon filter). When set to using carbon filters, every 120 hours, the microprocessor will indicate with a flashing ‘C’ on the display that the carbon filters need to be replaced. After replacing the carbon filters, cancel the warning message as follows: • Switch off the hood. • Press and hold Key 3 for more than 5 seconds. When the key is pressed the letter ‘C’ will appear on the display, after the 5 seconds the letter disappears and the microprocessor starts a new 120 hour count down to the next warning message. GB 10 CARE AND CLEANING LIGHT REPLACEMENT The hood can be provided with different types of lamps: incandescent, halogen and neon lamps. • Incandescent lamps (Fig.6): lamps with E14 cap, 40W power and 230V voltage, generally olive shaped. To replace them, remove the grease filters, unscrew the faulty lamp and screw in the new one, replace the grease filters. If using an electronic bulb, use only those with an E14 coupling,...

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории