Фрагмент инструкции
2 2 Filter First, turn the knob counter-clockwise, then detach the filter with sliding it in the direction of the arrow to disengage from the groove. Knob Filter cleaning Filter After immersing the filter in water with a mild detergent for 30 to 40 minutes, wash it with a toothbrush or the like to remove dirt. Clean the filter frequently to avoid grease contamination and grease build-up, which is difficult to clean. Enclosure/Rectifier Baffle Panel After wiping the enclosure and rectifier baffle panel off with a cloth immersed in a mild detergent, wipe off moisture thoroughly with a dry cloth. re-assembling 1 1 Filter Place the filter in the groove, hold it upward and turn the knob clockwise to fix it securely. 2 2 Rectifier Baffle Panel With holding the rectifier baffle panel by both hands, place it on the catches. Push the panel upward and slide it to engage the keyholes with 2 screws, then tighten the screws to fix the panel firmly. NOTE:Make sure that the rectifier baffle panel and filters are fixed in the appropriate positions correctly. Knob Filter replacing the light bulb Two 50W halogen light bulbs can be installed in this range hood. Prior to replacing the light bulb, purchase a halogen light bulb (PAR20 bulb, in the base diameter 26mm: medium base), rated 120V - 50W or below. 1 1 To remove the light bulb, turn it counter-clockwise. Then, replace the light bulb with a new one. NOTE: When replacing the bulb, wait until it has cooled off before removing, or you may burn your hand. To remove the light bulb To install the light bulb requesting service requesting service prior to requesting service Prior to requesting service, do the following check by yourself for common errors. Situation Check Range Hood does not oper ate . Range Hood is noisier than usual or vibrating. Is po w er s witch on at the ser vice panel? Is the filter contaminated b y g rease? Lamp does not tur n on. Is the b ulb brok en? Is the b ulb put in the soc k et correctly? NOTE • Service parts are kept at the manufacturer for a maximum of six years after ceasing the production of this model. • Requesting service indirectly can be done through contacting the dealer who sold this range hood to you. • When the range hood is not working normally even after checking common errors, please provide the following information to Fuji Industrial USA, Inc. (FIU). Fuji Industrial USA, Inc. 16300 Christensen Rd., Ste 212 Seattle WA98188-3403 Telephone: 1-888-547-9880 After Service Division Telephone: 1-866-FUJI IND (1-866-385-4463) a. Product --------------------------Range Hood b. Model Number-----------------ECW-300/360 c. Serial Number d. Date of purchase e. What is the problem? f. Owner's address g. Owner's telephone number h. Suggested date for service person's visit inspection label The model number and serial number are indicated on the inspection label, which is attached to the inside of the Range Hood. Remove the rectifier baffle panel to see it. Inspection label specifications specifications Refer to the following table. Model Voltage (V) Frequency (Hz) Speed Power Consumption (W) Air Flow (CMF) Noise Level (dB) at 0 Pa at 25 Pa Hi 255 430 410 52.0 ECW-300 120 60 Me 190 260 240 41.0 Lo 155 170 150 31.0 Hi 330 620 600 50.5 ECW-360 120 60 Me 255 360 350 39.5 Lo 220 180 160 25.0 NOTE FUJI INDUSTRIAL CO., LTD. has measured airflow under HVI-916 and noise levels under Japanese Industrial Standard (JIS) C9603 items 8.8 and 8.9. circuit diagram ECW-300 Fan Switch Lamp Switch 120V 60Hz Connector Connector Connector Connector Connector Connector Motor RedOrange Orange White White White PurplePurple White White White White Green Blue Blue Brown Brown Black Black Black Black Black White Black Black Grey GreyGrey Yellow Yellow Yellow Pilot Lamp Lamp Lamp Fan Switch Lamp Switch Capacitor Connector Pilot Lamp Lamp ECW-360 Lamp Capacitor 120V 60Hz Connector Connector Connector Connector Connector Motor Yellow Yellow RedOrange Orange White White White Purple Purple White White White White Black Green Blue Blue Brown Brown Black Black Black Black Black White Black Black Grey GreyGrey Yellow 11 No. No. Enclosure Front Panel Back Panel Fan Unit Case Motor Sirocco Fan Bellmouth Earth Wire Unit Switch Box Unit 1 2 3 4 5 6 7 8 9 Wire Box Unit Filter Rectifier Baffle Panel Exhaust Pipe Unit Mounting Bracket Outer Duct Inner Duct Attachment 10 11 12 13 14 15 16 17 15 16 14 13 1 13 15 16 14 1 10 8 2 7 6 5 9 4 3 11 10 8 2 7 6 5 4 9 3 11 12 12 ECW-300 ECW-360 Attachment Parts Name Parts Name Name of parts Figure Two(2) Pieces Four(4) Pieces Screw M4 . 10 Screw M5.1 . 45 Two(2) Pieces Wood Screw M4.5 . 45 17 parts list limited product warranty limited product warranty The Fujioh product warranty is to the original purchaser (consumer) of its products only and is not transferable. Fujioh warrants that its products will be free from defects in materials or workmanship for a period of three years from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPR...
Эта инструкция также подходит к моделям:Вентиляторы - ECW-360 (392.57 kb)