Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации AEG, модель E36DD75ESS

Производитель: AEG
Размер: 1.36 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Do not mount the vent on a slant or angle. Remove the knockout from the plenum by cutting the tape and metal cross overs to remove the insert. Loosely attach the anchoring legs to the left and right sides of the plenum using the hex nuts provided. Place the vent into the rear of the countertop cutout. Adjust the anchoring leg height so that the end caps are gently resting on the counter, then tighten the hex nuts. Secure the anchoring legs to the cabinet/floor with the screws provided. CONNECTING THE EXHAUST DUCT IMPOR IMPORIMPORIMPORIMPORIMPORT TTTTTANT ANTANTANTANTANT Use duct tape and sheet metal screws to seal the connection between the blower outlet and duct. Support the duct weight as necessary to ensure sealed joints. For the side or bottom knockouts use the supplied transition. For the rear knockout attach a 3 1/4" x 10" duct. 17 Installation MAKING THE ELECTRICAL CONNECTION ! WARNING WARNINGWARNINGWARNINGWARNINGWARNING • Ensure that the power supply is disconnected before proceeding. • Verify that the power supply matches the ratings found on the appliance data plate before proceeding. • The complete appliance must be properly grounded at all times when electrical power is applied. • Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire must be utilized. • If aluminum house supply wiring is used, splice the appliance copper wires to the aluminum house wiring with special connectors designed and agency-certified for this purpose. Follow the connector manufacturer’s recommended procedure carefully. Improper connection can result in a fire hazard. • Failure to complete electrical connections properly may result in a damaged or nonfunctional system. Follow the wiring diagrams carefully to ensure a proper installation. Both vent systems require a properly grounded, 120 VAC, 60 Hz., 15 Amp RVS electrical service. Maximum full line load is 8 amps. Always use a dedicated circuit. Do not use same circuit that the cooktop is using. Make all electrical connections between the vent and blowers, then connect power to the vent as per the wiring diagrams. Use wire nuts provided and electrical tape to secure all wiring connections at the blowers. See wiring diagram in Figure 5. Figure 5 GRN GRN 48” (1219mm) power cord with three prong grounded plug WHT BLK WHT BLK GRN GRN WHT BLK Blower WHT BLK 120VAC, 60Hz, 15A Wiring of RVS 18 Installation INSTALLING WITH A COOKTOP ! WARNING WARNINGWARNINGWARNINGWARNINGWARNING • The cooktops have very different installation requirement. Please make sure you read the Installation Instructions for the accompanying cooktop thoroughly before continuing the installation process. • After the cooktop has been installed ensure that the top cap on the vent intake does not catch on the back edge of the cooktop when the intake is lowered. If interference does occur, adjust the position of the cooktop by moving it against the front edge of the countertop cutout, then re-secure the cooktop to the countertop. Also, ensure that the vent anchoring legs have been properly secured to the cabinet base using the screws provided in the instructions envelope. Failure to eliminate interference may result in permanent damage to the vent. Operation 19 VERIFYING THE OPERATION ! WARNING WARNINGWARNINGWARNINGWARNINGWARNING • If the vent system is not operational after completion of the installation, do not attempt to repair it. See the Problem Solving section of the Use & Care Guide, then call a qualified service technician if the system is still not functional. • Always disconnect the appliances from the electrical power when servicing them. • Install the two (2) front filters and the grill prior to operating the vent. Refer to the Use & Care Guide for instructions regarding filter and grill installation. • Press the top cap up/down switch once to raise the vent to its operating position. • In the up position, turn the variable speed control switch in both directions to verify that the blower is operating correctly. • Press the top cap up/down switch once to lower the vent. Installation Instructions Installation InstructionsInstallation InstructionsInstallation InstructionsInstallation InstructionsInstallation Instructions External Blower Assembly for Electrolux Retractable Ventilation Systems E30DD75ESS E36DD75ESS E46DD75ESS E48DD75ESS 5995433678 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you have read the safety precautions in this manual. Safety items throughout this manual are labeled with a Warning or Caution based on the risk type. Definitions ! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. ! WARNING WARNINGWARNINGWARNINGWARNINGWARNING WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. ! CA CACACAC...

Эта инструкция также подходит к моделям:
Вентиляторы - E30DD75ESS (1.36 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории