Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Tradewins Furniture, модель RNC15

Производитель: Tradewins Furniture
Размер: 770.13 kb
Название файла: 28bb2c33-05b4-4294-8c50-06fa0fe74648.pdf

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


The device uses the stale air that is being exhausted to condition the fresh air as it is being brought in. General Required Tools Installation Tools • tin snips • large zip ties • assorted screw drivers • fabric flexible duct • electric drill -class II rated • hammer • mastic tape • wire strippers • alum. foil duct tape • knife • zip ties • caulking gun • 1/2” I.D. drain hose • smoke pencil Balancing Tools • Pitot Tube Balancing Kit [Case, 8 ft. vinyl tubing, Pitot tube, magnehelic gauge (0 -0.25”), and mounting plate] • Pitot Tube with instructions and Digital Manometer (with resolution of 0 -0.25” -must read to 1/100ths of an inch) Optional Accessories • 20 Minute Fan Timer • Wall Mounted Dehumidistat • Weather hood Kit • Round Diffuser 4” (100mm) 5” (125mm) 6” (150mm) 8” (200mm) • Kitchen Grille -may be required by code for kitchen applications -contains removable grease filter These instructions are intended as a general guide and do not supersede local codes in any way. Consult authorities who have jurisdiction before installation. Table of Contents Shipping and Packaging List .................................................1 Required Tools ......................................................................1 Application .............................................................................1 General..................................................................................1 Engineering Data................................................................2-3 Clearances & Requirements..................................................4 Installation ..........................................................................4-7 Installation Diagrams .............................................................8 Electrical ...............................................................................9 Optional Controls.................................................................10 Operation.............................................................................11 Wiring Diagrams ..................................................................12 Interlocking HRV to Furnace ...............................................13 Air Flow Balancing..........................................................15-16 Troubleshooting...................................................................17 Maintenance .......................................................................18 * LEAVE FOR HOMEOWNER NOTE: Due to ongoing research and product development, specifications, ratings and dimensions are subject to change without notice. TW-25 Engineering Data -HRV RNC15 THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the two air streams. It is easily removed for cleaning or service. MOTORS AND BLOWERS Each air stream has one centrifugal blower driven by a common PSC motor. FILTERS Washable air filters in exhaust and supply air streams. MOUNTING THE HRV Four threaded inserts at corners of case designed to accept four PVC reinforced polyester straps that are supplied with the unit. DEFROST Damper defrost system; defrosts automatically as the outdoor temperature falls. CASE Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensation. Drain connections two -1/2" (12mm) OD. WEIGHT 87 lbs. (39.5 kg) SHIPPING WEIGHT 89 lbs. (40.5 kg) CONTROLS HRV System Control HRV defaults to LOW SPEED when plugged in. HIGH SPEED option is accessible by connecting remote controls to designated terminals inside electrical box of HRV. Standard LOW SPEED SETTING can be increased by manipulating switches in electrical box. OFF(Standby)/LOW or OFF/HIGH speed operation also available by manipulating switches. OPTIONAL ACCESSORIES Performance Net supply air flow in cfm (L/s) against external static pressure E.S.P RNC15 (external static pressure) [cfm (L/s)] @ 0.1" (25 Pa) 177 (83) @ 0.2" (50 Pa) 164 (77) @ 0.3" (75 Pa) 156 (73) @ 0.4" (100 Pa) 143 (67) @ 0.5" (125 Pa) 123 (58) Max.Sensible Effectiveness 78% -13°F (-25°C) outdoor air 72°F (22°C) 40% RH indoor air Test Parameters 67cfm (32L/s) Sensible Effectiveness 32°F (0°C) 76% *Sensible Efficiency 32°F (0°C) 66% *Sensible Efficiency -13°F (-25°C) 60% **Latent Efficiency 95°F (35°C) 0% Total Efficiency 95°F (35°C) 20% VAC @ 60HZ 120 WATTS / High@.3” W.C. 173 WATTS / Low @.3” W.C. 63 99-132 20 Minute Fan Timer -(3 wire) 20 gauge wire (min.) 100’ length (max.) *Sensible Efficiency -thermal **Latent Efficiency -moisture Note: Effectiveness - based on temp. differential between the 2 airstreams99-186 Weather Hoods,2-6" (150mm) c/w 1/4" (6mm) screen Efficiency - includes parasitic losses from fan and defrosting 99-116 Dehumidistat Ventilation Control -Dehumidistat with ON/OFF 99-130 Dehumidistat Control -Dehumidistat All units conform to CSA and UL standards. 26.5" (673) Dimensions RNC15 inches (mm) BLOWERS FRESH AIR STALE AIR FROM OUTSIDE FROM INSIDE DAMPER DEFRO...

Эта инструкция также подходит к моделям:
Вентиляторы - RNC25 (770.13 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории