Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Hunter Fan, модель 82022

Производитель: Hunter Fan
Размер: 12.93 mb
Название файла: 42949.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


If you have questions, contact the manufacturer at the phone number or address listed in the warranty. 2. Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 5. Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible. 6. Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit. 7. Install fan at least 5 feet (1.52 m) above the floor. 8. Never place a switch where it can be reached from a tub or shower. 9. This unit must be grounded. CAUTION Warning DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT 1. For general ventilating use only. Do not use for ventilating hazardous or explosive materials. 2. To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward. 4. Please read specification label on product for further information and requirements. PREVENTATIVE MAINTENANCE A clean fan provides better service. Disconnect the power supply and clean the fan as listed below. TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders. TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. MAINTENANCE The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time. 42949-01 04/18/2007 2 x2EFGHIJKLMx4* * * NOTE:Strain relief cable connector must be installed. Not Included. ABC95044-01-09695029-01-00077869-01-00003242-01-23295491-07-00065222-01-23297258-01-000 75184-01-09297260-01-000 N76079-01-481 Extra Screwsx2D3/8” Cable Connector Check all the parts. If damaged, call 1-888-830-1326 for replacements. 2FJ 1 Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes Before Installation NOTE: Remove all packing materials before installation. Turn off the power source. Loosen screws. 42949-01 04/18/2007 3 3IF 4 5 6 7H 8G Remove packing material. Remove the motor/blower from the housing. Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover screw. Remove the wiring cover. 42949-01 04/18/2007 4 10BC 9F A12 A11F5/81/25/81/2 Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and secure with washer. Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below go to step D11, page15 New Construction - attaching to joist Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Screw pre-loaded screws into joist or framing. 42949-01 04/18/2007 5 A3 Pin2 PinFan MotorLightLightGreenBlackBlackWhiteBlackBlackWhiteWhiteBare CopperGroundA14 Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light Together *Option A13 A15FH 0A16 Route wires through the strain relief. Connect wires as shown. Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 42949-01 04/18/2007 6 A19J A20 0000IA18 0000A17 ONOFFA21 A22E1Go to stepon page 17 to attach grille. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. Turn on the power source. Secure the motor by tightening the 2 screws...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории