Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Hunter Fan, модель ELLIPSE 90063

Производитель: Hunter Fan
Размер: 9.3 mb
Название файла: 41722.pdf

Язык инструкции:enes

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


Use this unit only in a manner intended by the manufacturer. such as those published by the National Fire Prevention If you have questions, contact the manufacturer at the phone Association (NFPA), and the American Society for Heating, number or address listed in the warranty. Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 2. Before installing, servicing, or cleaning the unit, 5. When cutting or drilling into wall(s) or ceiling, do not disconnect the power by turning off the circuit breakers to damage electrical wiring or other hidden utilities. the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely 6. Ducted fans must always be vented to the outdoors. Keep attach a prominent warning device, such as a tag, to the ducting as short and as straight as possible. service panel. 7. Acceptable for use over a bathtub or shower when 3. Installation work and electrical wiring must be done by connected to a GFCI protected branch circuit. qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and 8. Install fan at least 5 feet (1.52 m) above the floor. standards. 9. Never place a switch where it can be reached from a tub 4. Sufficient air is needed for proper combustion and exhaust-or shower. ing of gasses through the flue (chimney) of fuel burning 10. This unit must be grounded. equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards, C a U T i O n W a r n i n g 1. For general ventilating use only. Do not use for ventilating hazardous or explosive materials. DISCONNECT 2. To avoid motor bearing damage and noisy/unbalanced ELECTRIC impellers, keep drywall spray, construction dust, etc. POWER SUPPLY off power unit. AND LOCK OUT 3. DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch SERVICE PANEL (45 degrees). Ductwork must point upward. BEFORE 4. Please read specification label on product for further information and requirements. SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service. Disconnect the power supply and clean the fan as listed below. TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders. TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. MAINTENANCE The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time. 2 41722-01 3/29/2006 41722_EngS_3.29.03.indd 2 3/29/06 10:54:39 PM x2 D E F G H I 95044-01-000 95022-01-000 75190-01-000 03242-07-133 95492-01-000 74508-03-133 J 95510-01-000 L 95366-01/02-000 K 75184-01-133 x5 * * * NOTE: Strain relief cable connector must be installed. Not Included. A B C x2 I Extra Screws 3/8” Cable Connector OFF 30 OFF 30 OFF 20 30 OFF 30 OFF 30 2 1 2 E I 3 Turn off the power source. Tools Needed. (Not supplied) Estimated assembly time: 30 to 60 minutes Before Installation Check all the parts. If damaged, call 1-888-830-1326 for replacements. Included. Loosen screws. 41722-01 3/29/2006 NOTE: Remove all packing materials before installation. 41722_EngS_3.29.03.indd 3 3/29/06 10:54:41 PM 5 7 G 8 F H E 3 6 4 Remove the motor/blower from the housing. Remove the pre-loaded screw tip covers. Remove the wiring cover screw. Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover. Remove packing material. 4 41722-01 3/29/2006 41722_EngS_3.29.03.indd 4 3/29/06 10:54:44 PM E 9 B C 10 E A11 5/8 1/2 5/8 1/2 A12 Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction – attaching to joist Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below go to step D11, page15 Screw pre-loaded screws into joist or framing. 41722-01 3/29/2006 5 41722_EngS_3.29.03.indd 5 3/29/06 10:54:46 PM A13 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black Red Red White Black Black White White Bare Copper Ground A14 Night Light Nig...

Эта инструкция также подходит к моделям:
Вентиляторы - ELLIPSE 90064 (9.3 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории