Фрагмент инструкции
This is normal. 3. Remove the blade mounting screws and rubber shipping bumpers from the motor. Medallion Blade Iron Figure 6c - Attaching Fan Blade to Blade Iron using Decorative Medallion continued 41343-01 41343-0141343-01 6/12/2002 7/1/2002 ® ® 4. For each blade, insert one blade mounting screw through the blade iron as shown in Figure 6d, and attach lightly to the fan. Insert the second blade mounting screw, then securely tighten both mounting screws. Figure 6d - Attaching Blade Irons to Hub of Fan Assembly 41343-01 7/1/2002 STEP 7 - ATTACHING THE SWITCH HOUSING ® The switch housing is made up of two sections: the upper switch housing, and the lower switch housing. ATTACHING THE UPPER SWITCH HOUSING 1. Partially install two #6-32 x 3/8" housing assembly screws into the switch housing mounting plate as shown in Figure 7a. Housing Assembly Screw Switch Housing Mounting Plate Upper Plug Connector Upper Switch Housing Figure 7a - Attaching Upper Switch Housing to Switch Housing Mounting Plate 2. Feed the upper plug connector through the center opening of the upper switch housing. See Figure 7a. 3. Align the keyhole slots in the upper switch housing with the housing assembly screws installed in sub-step 1. 4. Turn the upper switch housing counterclockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots as shown in Figure 7b. Install the one remaining #632 x 3/8" housing assembly screw into the third hole in the upper switch housing. Tighten all three screws firmly. CAUTION Make sure the upper switch housing is securely attached to the switch housing mounting plate. Failure to properly attach and tighten all three housing assembly screws could result in the switch housing and light fixture falling. Figure 7b - Mounting the Upper Switch Housing continued 41343-01 41343-0141343-01 6/12/2002 7/1/2002 ® ® ATTACHING THE LOWER SWITCH HOUSING Your hunter fan includes one of two lower switch housings. Both lower switch housings are shown in Figures 7c, 7d and 7e. The type of lower switch housing you have depends on whether your fan includes a light fixture, and if so, what type of light fixture it is. Use table 7-1 to assist you. Figure 7c Figure 7d Figure 7e Table 7-1 Fan with no light fixture included See Figure 7c Fan with single- globe light fixture See Figure 7c included Fan with multi- light light fixture See Figure 7d included Fan with integrated single globe See Figure 7e If your fan has a lower switch housing as shown in Figure 7c, and you ARE installing an accessory light kit or single-globe light fixture included with your fan, go directly to STEP 8 - INSTALLING LIGHT FIXTURE. continued 41343-01 7/1/2002 ® ® If your fan has a lower switch housing as shown in Figure 7c and you ARE NOT installing a light fixture, or if your fan has a lower switch housing as shown in Figure 7d or 7f, complete the following steps: 1. Connect the upper plug connector from the motor to the lower plug connector in the lower switch housing assembly. See Figure 7f. Note: Both plug connectors are polarized and will only fit together one way. Make sure that both connectors are properly aligned before connecting them together. Incorrect connection could cause improper operation and damage to the product. Upper Switch Housing Lower Plug Upper Plug Connector Connector Lower Switch Housing Housing Assembly Screw Figure 7f - Plug Connection and Lower Switch Housing Installation 2. Place the lower switch housing assembly over the upper switch housing. Align the side screw holes in the upper and lower switch housings. Attach the lower switch housing to the upper switch housing with three #6-32 x 3/8" housing assembly screws. See Figure 7f. Note: If your fan does not include a light fixture, you may purchase an accessory light kit separately. See STEP 8 - INSTALLING LIGHT FIXTURE. 41343-01 41343-0141343-01 6/12/2002 7/1/2002 ® ® STEP 8 - INSTALLING LIGHT FIXTURE Your fan may include a light fixture. Information for wiring and installing all included Hunter light fixtures follows. Note: If you purchased a fan without a light fixture, you may purchase an accessory light kit separately. For best performance and beauty, use only Hunter-brand light kits, Type A-Z. Hunter light kits are designed, tested, and UL approved for all Hunter fans, and are available at most Hunter dealers. To install the light kit, follow the instructions included with the kit. If you are not installing a light fixture, turn to OPERATING YOUR HUNTER FAN for additional instructions. WARNING • To avoid possible electrical shock, before installing light fixtures, disconnect power by turning off the circuit breakers both to the outlet box and to its associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel. • Connect house wiring to the fan before attaching the light fixture to the fan. • All wiring must be in accord...
Эта инструкция также подходит к моделям:Вентиляторы - Fan (292.05 kb)