Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации American Standard, модель ERVR100A9P00A

Производитель: American Standard
Размер: 45.19 kb
Название файла: 61e115a0-2079-4bd7-bb32-cca274395ac9.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


WARNING, AND CAUTION. These words are safety alert words. WARNING indicates hazards which could result in personal injury or death. CAUTION is used to indicate unsafe practices which could result in minor injury or property damage. ^WARNING! Disconnect Power Before Servicing. Failure to follow the electrical servicing instruction may cause Personal Injury or Death. ^WARNING! Do Not Use This Unit if Any Part Has Been Under Water. Immediately Call A Qualified Service Technician To Inspect The ERV and To Replace Any Part of The Control System Which Has Been Under Water. CAUTION! PERSONAL INJURY HAZZARD Failure to follow filter service instructions may cause personal injury. The access door swings down when unit is installed overhead. Carefully hold the access door while unlatching and lowering. The door should be removed prior to performing filter service. FILTER SERVICE. A Clean Filter Saves Money. When the ERV provides fresh outdoor air into your home and exhausts indoor air to the outside, dust and dirt particles build up on the air filters. Excessive accumulation can block airflow, decreasing the ERV’s performance and increase energy usage. To maintain top performance be sure to clean or replace the ERV filters according to the instructions in this manual. Clean filters every three months when the unit is in regular use or as needed to keep them clean. How to remove and clean your filter: 1. Release cam latches and carefully swing access door open. The access door may be removed for ease of service by sliding the access door off. Use caution when removing door 2. Remove the filter retainer springs. Pull the filters out. See Figure 1. 3. Vacuum filters off with a hose attachment. 4. Re-install filters and retainer spring 5. Re-install cover, and fasten cam latches. FILTER SERVICE NOTES A) The filters should be replaced after they have been cleaned several times. Contact your installing dealer for service and replacement filters. Replacement filter model numbers are as follows: Model Filter # *ERVR100 BAYFLT10A1010A *ERVR200 BAYFLT20A1020A *ERVR300 BAYFLT20A1020A B) Filters may be cut from a sheet or roll of .” - 1” firm, spun polyester filter “hog hair” media or material, similar to the existing, factory installed, green/blue filter in the unit. The size of each filter (2 required per unit) is listed as follows: *ERVR100 10 .” x 10 .” *ERVR200/300 10 .” x 21 .” * First letter of model number may be an “A” or “T”. C) Filters must always be used during unit operation or the heat transfer core will become blocked by particulate matter. The filters supplied in the unit are typically able to keep the heat transfer core clear for many months. Finer filters may be used but must be cleaned more often. HEAT TRANSFER CORE SERVICE. (The Heat Transfer Core may also be referred to as the Energy Exchange Element or Heat Exchanger) Vacuum the Face of the Heat Transfer Core Yearly. Particulate matter collects only on the entering faces of the heat transfer core. The interior of the heat transfer core stays clean even if the element faces are covered particulates. TO CLEAN THE HEAT TRANSFER CORE: 1. Remove filter retainer spring and the filters (see above). 2. Vacuum the exposed faces of the heat transfer core with a soft brush attachment. 3. After servicing the filters, re-install them and the filter retainer spring (see above). 4. Vacuum out dust from the rest of the unit case. ! CAUTION DO NOT WASH THE HEAT TRANSFER CORE. Always handle the core carefully. Keep it away from water or fire to avoid damaging it. The heat transfer core can be replaced but is expensive. User’s Information Heat Transfer Core Filter Retainer Figure 1 Energy Recovery Ventilator with cover removed Power Light Runtime % Lights Press Fan icon on touchpad one or more times to obtain desired Press Fan icon on Runtime (Press once touchpad one or for 20 minutes, twice more times to obtain for 40 minutes, three desired Runtime %. times for 60 minutes) Press the Fan icon for 5 seconds to cancel. Figure 2 Figure 3 Percent Timer (P.T.) Control Optional Push Button Control User’s Information PERCENT TIMER CONTROL (PT) The Percent Timer Control automatically energizes and de- energizes the energy recovery ventilator every hour, ensuring ventilation for the home around-the-clock. The PT control has two status lights (See Figure 2). One is the power light located in the upper left hand corner of the control. The other light will be one of the Runtime % lights. The power light is on whenever the PT control is calling for the ERV to run. The Runtime % light is located along the right side of the control. The Runtime % light indicates the amount of time per hour the ERV will operate. Set the control per your local code or ASHRAE Std 62.2 and your ventilator will run once every hour. FOR CONSTANT OPERATION: Press the fan icon until the 100% light is on. The “Runtime %” light turns on. The ERV unit will run continuously. FOR MINIMUM VENTILATION REQUIREMENT OPERATION...

Эта инструкция также подходит к моделям:
Вентиляторы - ERVR300A9P00A (45.19 kb)
Вентиляторы - ERVR200A9P00A (45.19 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории