Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Vermont Casting, модель DVRSR

Производитель: Vermont Casting
Размер: 704.74 kb
Название файла:

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


Adjust sleeve to maximum (10-3/8 x 9-3/8). and attach to firestop with #8 sheet metal screws (supplied). (Fig. 12) Install firestop assembly. - 9 #8 SCREWS(2) ADJUSTABLE ZERO CLEARANCE SLEEVE ADJUSTABLE ZERO CLEARANCE SLEEVE #8 SCREWS(2) #8 SCREWS(2)Maximum Length 12" (294mm) FIRESTOP Fig. 12 STEP 3 Measure from fireplace collar to face of outside wall (add 2" for vent pipe overlap. Mark pipes and cut to length. It is very important that the two pipes are flush with the outside wall once the fireplace is in its final location. Fig. 13. #8 SCREWS(2) ADJUSTABLE ZERO CLEARANCE SLEEVE ADJUSTABLE ZERO CLEARANCE SLEEVE #8 SCREWS(2) #8 SCREWS(2)Maximum Length 12" (294mm) FIRESTOP Fig. 12 STEP 3 Measure from fireplace collar to face of outside wall (add 2" for vent pipe overlap. Mark pipes and cut to length. It is very important that the two pipes are flush with the outside wall once the fireplace is in its final location. Fig. 13. STEP 4 Slip 4" and 7" pipes onto respective flue collars. Make sure to fix to the fireplace collar the 4" pipe with three (3) screws before fixing the 7" pipe on the 7" collar. Both pipes must be on a level plane. Fig. 13. STEP 5 Guide the vent termination 4" collar into the 4" pipe then the 7" collar into the 7" pipe. Do not force the venting into position. If the pipes do not line up with the termination collars, disassemble pipes and reattach to the fireplace collar. (Fig. 13) STEP 6 Secure fireplace to floor through floor holes and adjustable frame drywall strip (nailing flange) to frame. (See Framing & Finishing Section) Fig. 13 VERTICAL SIDEWALL APPLICATIONS Vent Starter Kit 7DVSK, plus Transition Elbow 7DVRT90 must be used in Vertical Sidewall installations. The 4" pipe must be centred inside the 7" pipe coming off the 7DVRT90 transition elbow. Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to. The graph showing the relationship between vertical and horizontal side wall venting will help to determine the various vent lengths allowable. Fig. 19. Minimum clearance between vent pipes and combustible materials is one (1") inch (25 mm) on top, bottom and sides unless otherwise noted. When vent termination exits through foundation less than 20" below siding outcrop, the vent pipe must flush up with the siding. A 7DVSS must also be used. It is always best to locate the fireplace in such a way that minimizes the number of offsets and horizontal vent length. The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace to the face of the outer wall. Horizontal plane means no vertical rise exists on this portion of the vent assembly. For some installations, it may be desireable to have some amount of the horizontal vent run immediately after the fireplace. A vertical rise must be used but can be located anywhere in the vent system, to meet the perimeters identified in the venting graph. The maximum horizontal vent run is 20 feet (6100mm) when the vertical vent rise is 7.5 feet (2286mm). Fig. 14 7.5' 90" (2286mm) 20ft. (6100mm) 48" (1220mm) (305 mm) 12"15ft. (4572 mm) VENT TERMINATION MAXIMUM SIDE VIEW 7DVT90 ELBOW Vertical Dimension 8ft. minimum when horizontal run is 20 ft. Fig. 14 - 10 - 11 - Fig. 17 For each 45 degree elbow installed in the horizontal run (while maintaining a constant horizontal plane), the length of the horizontal run MUST be reduced by 18" (457mm). This does not apply if the 45 degree elbows are installed on the vertical part of the vent system. If a 90 degree elbow is used in the horizontal vent run (level height maintained) the maximum horizontal vent length is reduced by 36 inches. Fig. 18. This does not apply if the 90 degree elbows are used to increase or redirect a vertical rise. Example: According to the vent chart the maximum horizontal vent length is 20 ft.when the vertical height is 8 ft. from fireplace base height. If one 90 degree elbow is required in the horizontal vent it must be reduced to 17 ft. 120" 3048mm 90. elbow=3' 7' 90" 2286mm 84" 2134mm SIDE VIEW Fig. 15 Fig. 16 When one 90. elbow is installed directly onto another off the back of the fireplace the maximum horizontal vent length is 36" (914mm). Fig. 16. VERTICAL SIDEWALL APPLICATIONS The maximum number of 90 degree elbows per side wall installation is four (4), (includes 7DVRT90 off back of unit) The maximum number of 45 degree elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run. The maximum number of elbow degrees in a system is 270.. (This does not include transition elbow from rear vent to vertical vent). Fig. 15 Sample: 1 - 90. 2 - 45. 3 - 45. 4 - 90. Total - 270. HOW TO USE THE VENT GRAPH HOW TO USE THE VENT GRAPH 1. Determine the height of the centre of the horizontal vent pipe exiting through the outer wall. Usin...

Эта инструкция также подходит к моделям:
Вентиляторы - DVRS3 (704.74 kb)
Вентиляторы - DVRSL (704.74 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории