Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Field Controls, модель B-34TJ

Производитель: Field Controls
Размер: 598.3 kb
Название файла: 46107700.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


NOT CSA CERTIFIED FOR SOLID FUELS. The regulator contained in this package is manufactured with careful precision. It is designed to regulate chimney draft with a high degree of accuracy and fuel efficiency. English .......Page 1 Francais .....Page 4 Espanol ......Page 6 INSTALLATION OF TEE SECTION Locate the draft control as near to the furnace or boiler as possible. If the installation has a smokepipe stack control, locate the regulator at least 18" away from the stack control. (See Figures 3-9) FOR WOOD FUEL When burning wood, creosote builds up in the flue pipe. For this reason the tee should be assembled so that the beaded and crimped end is pointed downward. This prevents seepage at the joints. (See Figure 1) FOR OTHER FUEL Install tee with beaded and crimped end pointed upward. (See Figure 2) NOTE: Damper must be mounted with the hinge pins horizontal and the face of the damper plumb for correct operation. This is done by rotating the damper section within the collar for any pipe position. Tighten screw to hold firmly in place. Figure 1 Figure 2 BEST LOCATIONS FOR OIL OR SOLID FUELS Figures 3-8 *Selected sizes CSA and UL approved. Not CSA certified for solid fuels. Figure 9 Page 2 BALANCING WEIGHT ASSEMBLY AND DRAFT ADJUSTMENT TYPE B-34 (See Figure 10) 1. Assemble the “counter balance weight assembly” to the draft control as shown in Figure 10 Thread “counter balance weight” through “threaded nut” attached to the vane. Assemble “hex nut” and “knurled nut” on front of vane as shown in Figure 10. 2. Turn “knurled nut” counter clockwise for less draft, clockwise for more draft. 3. When adjustment is made for desired draft, lock the “counter balance weight assembly” in place by tightening the “hex nut” located under the “knurled nut” against the vane. Figure 10 TYPE DR (See Figure 11) 1. Assemble the “carriage bolt” through the “weight support bracket” attached to vane. 2. Thread tapered “counter balance weight” on “carriage bolt” (tapered portion of weight must point toward bottom of draft control). For less draft, slide “counter balance weight assembly” toward “Lo” position marked on the bracket; for more draft, slide “counter balance weight assembly” toward “Hi” position. 3. When adjustment is made for desired draft, tighten weight securely to “carriage bolt”. Vertical installation: The 8” and 9” sizes, when mounted in vertical installations only, require a small screw and nut (supplied) assembled in the hole at the bottom vane. The 6” and 7” regulators do not require this additional hardware in vertical installation. WOOD AND COAL FIRED APPLICATIONS 1. Installations of this Draft Control should be made in accordance with the stove manufacturer's instructions. When this is not possible, follow the directions below: (NOTE: For the regulator to operate properly, the chimney must be clean and free of obstructions. 2. The best setting for wood and coal burners is a draft gauge reading of .04” to .08 W.C. If a draft gauge is not available, with the draft regulator fully installed and a good fire burning, adjust the counterbalance weight closer to the gate for as low a draft setting as possible, without the fire dying or getting smoke-back with the stove door slightly open. To obtain higher heat levels, move the weight away from the gate to increase the setting. 3. For best combustion efficiency, stack temperature (below the draft regulator) should be 350° to 450° F for dry wood. Recommended stack temperatures and draft settings for coal vary according to the manufacturer of the stove. OIL FIRED APPLICATIONS Proper operation of the regulator depends upon proper installation and adjustment. Use a CO2 indicator, stack thermometer and draft gauge to adjust draft for oil fired burners. Domestic oil burners work best with the draft over fire of .01 to .02-inches W.C. Figure 11 Page 3 INSTALLATION DE LA SECTION EN “T” Placer le regulateur de tirage aussi pres de la fournaise ou de la chaudiere que possible. Si l’installation est dotee d’une commande de tuyau de cheminee, placer le regulateur a au moins 18 po de cette commande. (Voir les Schemas 3-9) POUR BOIS DE CHAUFFAGE Lorsqu’on fait bruler du bois, de la creosote se forme a l’interieur du tuyau de fumee. Pour cette raison, le joint en “T” devrait etre assemble de facon que le bout embouti et ondule pointe vers le bas. Cela evite le suintement aux joints. (Voir le Schema 1) POUR AUTRE COMBUSTIBLE Installer le joint en “T” de facon que le bout embouti et ondule pointe vers le haut. (Voir le Schema 2) NOTA: Le registre doit etre monte de facon que les axes de charnieres soient a l’horizontale et que la face du registre soit d’aplomb, pour assurer un fonctionnement adequat. Pour ce faire, tourner la section de registre a l’interieur du collier pour toute position de tuyau. Serrer la vis pour bien tenir en place. Schema 1 Schema 2 Schema 9 MEILLEURS EMPLACEMENTS POUR Schemas 3-8 MAZOUT OU COMBUSTIBLES SOLIDES * Formats selectionnes approuves UL et ACNOR. Non certi...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории