Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Xpelair, модель PW302210R

Производитель: Xpelair
Размер: 169.46 kb
Название файла: 24c87d75-82c6-9d54-6dff-2d9a8326ecdf.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Follow the dimensions shown in the Installation illustration on page 4. Wolf Pro wall hoods are shipped without a blower assembly. Internal, in-line or remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for Pro ventilation recommendations and blower options. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro wall hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection. Locate electrical within the shaded area shown in the Installation illustration on page 4. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. Refer to the installation instructions shipped with each Wolf product for detailed specifications. This information can also be found on our website, wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Planning Information Pro Low-Profile Wall Ventilation Hood MODEL PW302210(R) DUCTING CONSIDERATIONS Wolf Pro low-profile wall hoods are shipped without the blower assembly. Internal, in-line and remote blower assemblies are available. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro low-profile wall hoods come standard with a horizontal or vertical discharge. No transition is included. Internal blower WBLOWER-50INT comes with a transition. When using an in-line or external blower, use the optional accessory 10" (254) round transition. The hood will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific requirements in your area. IMPORTANT NOTE: Wolf Pro low-profile wall hoods must be vented to the outside except when used with the accessory recirculating kit with the 600 CFM blower. Use only metal ductwork. Refer to the illustration below for ducting considerations for Pro low-profile wall hoods. Ducting for Pro low-profile wall hoods. DUCTWORK INSTALLATION THROUGH ROOF 22" (559) DEPTH OF HOOD 10" (254) ROUND DUCT SOFFIT OR CABINET OR DUCT COVER VERTICAL DISCHARGE 173/4"W x 41/4"D TO 10" ROUND 93/8"H (INCLUDING FLANGES) ACCESSORY TRANSITION FOR IN-LINE OR REMOTE BLOWER 30" TO 36" (762–914) COUNTERTOP TO BOTTOM OF VENTILATION HOOD 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT 10" (254) HEIGHT OF HOOD WALL HOOD ROOF CAP OR REMOTE BLOWER NOTE: 10" (254) ROUND ACCESSORY TRANSITION SHOWN IN VERTICAL DISCHARGE APPLICATION WITH IN-LINE OR REMOTE BLOWER. REFER TO INSTALLATION INSTRUCTIONS FOR HORIZONTAL DISHCARGE. Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Planning Information Pro Low-Profile Wall Ventilation Hood MODEL PW302210(R) WOLF BLOWER ASSEMBLIES A ventilation system must include a blower assembly. Wolf ventilation hoods are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and homeowner preferences. Internal, in-line and remote blower assemblies are available as sales accessories through your Wolf dealer. IMPORTANT NOTE: Use only a Wolf blower with all Wolf ventilation products. Internal blowers are mounted inside the hood canopy. In-line blowers are mounted in between the hood and the exterior of the home. Remote blowers can be mounted on the roof or in some cases, on an exterior wall. Refer to the illustrations below for dimensions of Wolf in-line and remote blowers. Pro ventilation recommendation charts on the following page provide minimum CFM recommendations according to the cooking appliance and ventilation hood used and blower options for each specific Pro low-profile wall hood. 241/2" (622) 151/2" (394) 281/4" (718) 203/4" (527) 243/4" (629) 14" (356) 43/4" (121) 10" (254) Diameter 113/4" (298) 211/2" (546) 243/8" (619) 181/2" (470) 121/4" (311) 41/2" (114) In-line BLOWER-60IL Remote BLOWER-60REM and BLOWER-90REM Unit dimensions may vary by ± 1/8" (3). Dimensions in parentheses are in millimeters unless otherwise specified. 7 Planning Information Planning Information Pro Low-Profile Wall Ventilation Hood MODEL PW302210(R) PRO VENTILATION CFM RECOMMEND A TIONS Pro Low-Profile Wall Hoods Model DF304 / R304 / SRT304 DF366 / R366 / SRT366 / RT366 DF364 / R364 / SRT364 / RT364 RT362 DF484 / R484 / SRT484 / RT484 PW302210 500/600 PW362210 500/600 900 900 900 PW422210 900 900 900 PW482210 900 MinimumCFMrequirementsfor Wolfrangesandrangetops.CFMrecommendationsare based ontotal Btu/hr output. Additional CFMmayberequiredfor long duct runs. PRO VENTILATION BLOWER OPTIONS Pro Low-Pr...

Эта инструкция также подходит к моделям:
Вентиляторы - PW302210R (169.46 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории