Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Smeg, модель KIV90XT

Производитель: Smeg
Размер: 498.44 kb
Название файла: 914774437-GB.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


EN3 CHARACTERISTICS Dimensions EN4 EN 55 Components Ref. Q.ty Product Components 1 1 Hood Canopy complete with: Controls, Lights, Filters 2 1 Telescopic chimney made up of: 2.1 1 Upper chimney 2.2 1 Lower chimney 7.1 1 Telescopic frame complete with Suction fan, made up of: 7.1a 1 Upper frame 7.1b 1 Lower frame 8a 1 Rh Air Outlet Directional Grille 8b 1 Lh Air Outlet Directional Grille 9 1 Reduction flange o 150-120 mm 10 1 Dumper 14.1 1 Air Outlet Connector Extension 15 1 Air Outlet Connector 24 1 Connection box 25 Pipe clamps (not included) 26 2 Cable clamps 27 1 Finishing plug Ref. Q.ty Installation Components 11 4 Wall Plugs o 10 12c 6 Screws 2,9 x 6,5 12e 2 Screws 2,9 x 9,5 12f 2 Screws M4 x 80 12g 4 Screws M6 x 80 12h 4 Screws 5,2 x 70 12q 4 Screws 3,5 x 9,5 21 1 Drilling template 22 8 6.4 mm int. dia washers 23 4 M6 nuts Q.ty Documentation 1 Instruction booklet INSTALLATION Drilling the Ceiling/shelf and fixing the frame DRILLING THE CEILING/SHELF • Use a plumb line to mark the centre of the hob on the ceiling/support shelf. • Place the drilling template 21 provided on the ceiling/support shelf, making sure that the template is in the correct position by lining up the axes of the template with those of the hob. • Mark the centres of the holes in the template. • Drill the holes at the points marked: • For concrete ceilings, drill for plugs appropriate to the screw size. • For hollow brick ceilings with wall thickness of 20 mm: drill o 10 mm(immediately insert the Dowels 11 supplied). • For wooden beam ceilings, drill according to the wood screws used. • For wooden shelf, drill o 7 mm. • For the power supply cable feed, drill o 10 mm. • For the air outlet (Ducted Version), drill according to the diameter of the external air exhaust duct connection. • Insert two screws of the following type, crossing them and leaving 4-5 mm from the ceiling: • For concrete ceilings, use the appropriate plugs for the screw size (not provided). • for Cavity ceiling with inner space, with wall thickness of approx. 20 mm, Screws 12h, supplied. • For wooden beam ceilings, use 4 wood screws (not provided). • For wooden shelf, use 4 screws 12g with washers 22 and nuts 23, provided. EN6 EN 77 Fixing the frame • Loosen the two screws fastening the lower chimney and remove this from the lower frame. • Loosen the two screws fastening the upper chimney and remove this from the upper frame. If you wish to adjust the height of the frame, proceed as follows: • Unfasten the metric screws joining the two columns, located at the sides of the frame. • Adjust the frame to the height required, then refit all the screws removed as above. • Insert the upper chimney stack from above, and leave it running free on the frame. • Lift up the frame, fit the frame slots onto the screws up to the slot end positions. • Tighten the two screws and fasten the other two screws provided with the hood. Before tightening the screws completely it is possible to adjust the frame by turning it. Make sure that the screws do not come out of their seats in the slotted holes. • The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device. On completion, check that the base is stable, even if the frame is subjected to bending. • In all cases where the ceiling is not strong enough at the suspension point, the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts. Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe o 150 or 120mm, the choice of which is left to the installer. To install a o 150 pipe • To install the dumper 10 • Fix the pipe in position using sufficient pipe clamps (not supplied). To install a o 120 pipe • To install a o 120 mm air exhaust connection, insert the reducer flange 9 on the dumper 10. • Fix the pipe in position using sufficient pipe clamps (not supplied). • Remove any activated charcoal filters. EN 88 RECIRCULATION VERSION AIR OUTLET • Assemble the two halves of the hood body extension piece 14 (if necessary). • Push fit the assembled hood body extension piece 14 onto the air outlet (if necessary). • Push fit connection 15 onto the hood body extension piece 14 or directly onto the hood body. • Insert the connection extension pieces laterally 14.1 in connection 15. Should the central reinforcing piece of the frame somehow interfere the chimney air outlet grille, it is possible to unscrew it and to place it in another screw hole set. Flue assembly - Mounting the hood body • Position the upper chimney section and fix the upper part to the frame using the 2 screws 12c (2,9 x 6,5) provided. • Similarly, position the lower chimney section and fix the lower part to the frame using the 2 screws 12c (2,9 x 6,5) provided. Recirculation version...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории