Войти:
Оценок - 5, средний балл: 4.2 ( )

Инструкция по эксплуатации Smeg, модель Arco Isola Plus KSEIV96X

Производитель: Smeg
Размер: 430.57 kb
Название файла: KSEIV96X-GB.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe o 150 or 120 mm, the choice of which is left to the installer. • To install a o 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. • Fix the pipe using the pipe clamps 25 provided. • Remove any activated charcoal filters. RECIRCULATION VERSION AIR OUTLET • Insert reducer flange 9 on the extractor outlet. • Push fit the extension piece 14 onto the flange. • Push fit connector 15 onto the extension piece. • Insert extension piece/connector 14.1 laterally on connector 15, ensuring that the outlet is in line with the chimney intake. 9 o 150 o 120 15 14.1 14 9 Flue assembly - Mounting the hood body • Position the upper chimney section and fix the upper part to the frame using the 2 screws 12c provided. • Fit the lower chimney section onto the frame, holding it in place until the hood body has been fixed in place. Recirculation version • Make sure that the outlet of the extension piece 14.1 is horizontally and vertically aligned with the chimney outlet. • If this is not the case, remove the lower chimney section and adjust the position by cutting the hood body extension 14 along one of the thinner section channels denoting the pre-fixed lenghts, then reassemble as described previously. Before fixing the hood body to the frame: • Remove the grease filters from the hood body; • Remove any activated charcoal filters. 12f8 • From below, use the 4 screws 12f provided to fix the hood body to the frame. • For the recirculation version, locate the directional grill 8 in its housing. Ensure that it is inserted correctly in connector 15. ELECTRICAL CONNECTION • Connect the hood to the mains through a two- pole switch having a contact gap of at least 3 mm. 18GB • Connect the control connector Cmd. • Connect the lights connector Lux. • Place the connectors in the junction box 24 and close it using the 2 screws 12e (2,9 x 9,5) provided. • Fix the junction box to the hood body using the 2 screws 12c (2,9 x 6,5) provided. • For the recirculation version, fit the activated carbon odour filter. • Replace the grease filters. USE Control panel L Light Switches the lighting system on and off. S1 Led Motor running led. Flashes when the grease filters are saturated. S2 Led Intensive speed led. Flashes when the activated carbon odour filters are exhausted. M Motor Switches the extractor motor on and off at low speed. Used to provide a continuos and silent air change in the presence of light cooking vapours. When the Hood is in ELC (Electronic Comfort) mode, the button will not only turn the Ducting motor on, but will also disable this function. V1 Speed Reduces the operating speed. When the button is pressed with the Motor off, ELC (Electronic Comfort) mode will be enabled again, giving a continuous, low noise flow of air. Press the button and hold it until Led S1 flashes slowly. V2 Speed Increases the operating speed. V3 Intensive Maximum speed, used for eliminating the highest cooking vapour emission. speed Switches off automatically after 10 minutes operation. Can also be switched off manually by pressing the button. 19GB MAINTENANCE Grease filters CLEANING METAL SELF-SUPPORTING GREASE FILTERS Alarm signal reset • Switch off the lights and extractor motor. • Press button V3 for at least 3 seconds, until the leds start to flash. Cleaning the filters • The filters are washable and must be cleaned when led S1 flashes or at least every 2 months of operation, or more frequently for particularly heavy usage. • Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time. • Wash the filters, taking care not to bend them. Allow them to dry before refitting. • When refitting the filters, make sure that the handle is visible on the outside. 20GB Activated charcoal filter (Recirculation version) REPLACING THE ACTIVATED CHARCOAL FILTER • The filter is not washable and cannot be regenerated. It must be replaced when led S2 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on. Alarm signal reset • Switch off the lights and extractor motor. • Press button V3 for at least 3 seconds, until the leds start to flash. Replacing the Filter • Remove the metal grease filters • Remove the saturated activated carbon filter by releasing the fixing hooks • Fit the new filter by hooking it into its seating • Replace the metal grease filters. Alarm signal activation • On the recirulcation version extractor hood, the filter saturation alarm is activated during installation or at a later date. • Switch off the lights and extractor motor. • Press button V3 for at least 10 seconds, until the leds start to flash: • 2 flashes of the activated carbon odour filter saturation alarm led = filter ACTIVATED • 1 flash of the activated carbon odour filter saturation alarm led = filte...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории