|
Фрагмент инструкции
Discharge Vertical ACCESSORIES Platinum or brass decorative rail and stand-offs 38" (965) high stainless steel backsplash with warming racks 38" (965) high stainless steel backsplash 6" (152), 12" (305), 18" (457) and 24" (610) duct covers Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com. Duct Size 10" (254) Round Electrical Supply Requirements 110/120 V AC, 60 Hz 15 amp dedicated circuit Shipping Weight (shell only) 106 lbs (48 kg) Specifications are subject to change without notice. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information Planning Information Pro 54"(1372) Wall Chimney Hood MODEL PWC542418(R) INSTALLATION SPECIFICATIONS – – NOTE: Pro wall chimney hoods have a vertical discharge. DIMENSIONS Overall Width of Hood 54" (1372) Overall Height of Hood 18" (457) Overall Depth of Hood (excluding rail) 24" (610) Countertop to Bottom of Hood 30" (762) to 36" (914) Location of Electrical Within shaded area See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information Planning Information Pro 54" (1372) Wall Chimney Hood MODEL PWC542418(R) INSTALLATION NOTES Refer to the illustrations and specifications for overall dimensions and installation specifics. Wolf Pro wall chimney ventilation hoods are recommended for use with any Wolf cooking appliance, and should be as least as wide as the cooking surface. It is recommended that the hood overlap the cooking surface by 3" (76) on either side. Optional 6" (152), 12" (305), 18" (457) and 24" (610) duct covers are available as a sales accessory to complete the chimney design. Installation of all Pro wall chimney hoods should be 30" (762) to 36" (914) from the bottom of the hood to the countertop. Follow the dimensions shown in the Installation illustration. Wolf Pro wall chimney hoods are shipped without a blower assembly. Internal, in-line or remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to page 8 for Pro Ventilation CFM Recommendations and Blower Options. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro wall chimney hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection. Locate electrical within the shaded area shown in the Installation illustration. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. Refer to the installation instructions shipped with each Wolf product for detailed specifications. This information can also be found on our website, wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Planning Information Pro 54" (1372) Wall Chimney Hood MODEL PWC542418(R) DUCTING CONSIDERATIONS Wolf Pro wall chimney ventilation hoods are shipped without the blower assembly. Internal, in-line and remote blower assemblies are available. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Wolf Pro wall chimney hoods have a vertical discharge location with 10" (254) round duct. A transition with backdraft damper is included. The hood will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific requirements in your area. IMPORTANT NOTE: Wolf Pro wall chimney hoods must be vented to the outside. Use only metal ductwork. Refer to the illustration below for ducting considerations for Pro wall chimney hoods. Ducting for Pro wall chimney hoods. DUCTWORK INSTALLATION THROUGH ROOF 24" (610) DEPTH OF HOOD ROOF CAP OR REMOTE BLOWER 10" (254) ROUND DUCT SOFFIT OR CABINET OR DUCT COVER NOTE: VERTICAL DISCHARGE ONLY FOR PRO WALL CHIMNEY HOODS. VERTICAL DISCHARGE TRANSITION 14"W x 93/4"D TO 10" ROUND 7"H (INCLUDING FLANGES) 30" TO 36" (762–914) COUNTERTOP TO BOTTOM OF VENTILATION HOOD 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT 18" (457) HEIGHT OF HOOD 163/4" (425) TOP OF WOOD MOUNTING STRIP WALL HOOD Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Planning Information Pro 54" (1372) Wall Chimney Hood MODEL PWC542418(R) WOLF BLOWER ASSEMBLIES A ventilation system must include a blower assembly. Wolf ventilation hoods are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and homeowner preferences. Internal, in-line and remote blower assemblies are ava...
Эта инструкция также подходит к моделям:Вентиляторы - PWC542418R (205.16 kb)