The cut-out device will reset itself when the fan motor has cooled significantly. NOTE: This hood has been designed and approved for installation over an electric hob with a maximum input of 7kW or a gas hob with a maximum input of 10kW when fitted in accordance with the heights recommended above. Your Cooker Hood can be installed either for recirculation back to the room or extraction through an outside wall. When used in the extraction mode the Cooker Hood ducting must not be connected to a flue which is used for exhausting fumes from a central heating flue or water heating flue. IMPORTANT: The exhaust air must not be expelled through a smoke or waste-gas chimney which is in use or through a shaft used for ventilating rooms or into the cavity of a cavity wall or into a cupboard above the cooker hood. If the room contains, a flued fuel burning appliance, such as a gas or oil fired central heating boiler which is not of the ‘Balanced Flue’ type, you should make sure that there is adequate air inlet into the room at all times, so that fumes from the boiler are not drawn back into the room by the Cooker Hood. NOTE: All installations must comply with local authorities and building regulation requirements for the discharge of exhaust air into the atmosphere. All the fittings are supplied. If the hood is to be installed onto a hollow construction or plaster board wall, then special fixings will have to be purchased. Before drilling, care should be taken to check for electric cables, water pipes or gas pipes in the location where the cabinet/canopy is to be fitted. If the hood can only be fixed to a hollow construction plaster or partition board structure, then the wall must be sufficiently reinforced to be quite rigid in the area of the mounting brackets. To avoid the risk of accidents when fitting the canopy and chimney to the wall or ceiling please read and follow the installation instructions. For ease of installation proceed as follows: 1. Fix the wall brackets. 2. Fix the canopy hood. 3. Connect the hood to the mains supply ensuring that the canopy is functioning correctly. 4. Select the type of installation, ie. ducting or recirculation. 5. Fix the chimney stack. NOTE: The hood is more efficient in the exhaust mode, therefore, this position should be selected during the warmer months of the year when no heating is being used. When the room is being heated, if the recycle position is selected heat will not be wasted. Installing your Cooker Hood Wall Mounted Model Lower Fixings 1. Draw a vertical line on the wall, from the centre of the cooking appliance, up to the ceiling. Check the line is vertical using a spirit level. 2. Put the template provided on the wall paying particular attention to positioning distances (see page 5). 3. Drill two holes (Fig.6 2) and insert wall plugs. 3. Fit two hooks in the drilled holes (Fig.6 4) using screws (Fig.6 5). Upper Fixing Bracket 1. Draw a horizontal line through the vertical line, 15mm from the ceiling. Check the line is level using a spirit level. 2. Place the chimney support bracket (Fig.6 13) over the line, ensuring the bracket is level. Mark the positions for the fixing screws (Fig.6 14). Fig.6 3. Drill the two holes for the wall bracket, insert the wall plugs and fit the bracket using the screws provided. If the hood is to be installed onto a hollow or plasterboard wall, special fixings will be required. FIXING THE CANOPY HOOD: 1. Remove the metal filter. 2. Hang the rear of the hood canopy on the hooks and adjust the position of the hood using the adjusting screws (Fig.6 6 & 7). 3. Whilst the hood is positioned, mark the two holes (Fig.6 9). 4. Remove the hood and drill the two holes. Insert the wall plugs, return the hood to the hooks and fix in place with the two screws (Fig.6 10). Installing your Cooker Hood RECIRCULATION: The chimney hood is supplied specified for installation in the extraction mode. To convert to recirculation it will be necessary to obtain the optional carbon filter. In the recirculation mode, contaminated air enters the chimney hood and passes through the grease filter and carbon filter and then out into the kitchen through two grilles, at either side of the chimney. To convert the chimney hood to recirculation proceed as follows: 1. Remove the metal grease filter, push the securing tabs towards the centre and pull the filter downwards (Fig.7). Fig.7 Fig.8 3. Push the metal grease filter back into place. 4. Fit the recirculation spigot (Fig.6 15F) to the ducting pipe as illustrated on the installation instructions. NOTE: The two venting grilles must not be fitted into the chimney stack until the chimney stack has been installed onto the wall above the canopy. 2. Fit the carbon filter and secure to the hood with two screws provided (Fig.8). EXTRACTION: Ducting Fitting The chimney hood can be ducted to the outside, using either rigid or flexible ducting of 150mm. The choice of ducting is left to the discretion of the installer, however, th...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории