|
Фрагмент инструкции
Nos: TSR12CW TSR18CW TSR24CW TSR12ACW TSR18ACW TSR24ACW C( This appliance conforms to îhe following EEC Directives: low Voltage Equipmenl Electromagnetic Compatibility 73/23/EEC 89/336/EEC 93/68/EEC 92/31 /EEC 93/68/EEC IMPORTANT NOTES: It is important to read these instructions carefully and also note the information given on the heater itself. As these particular instructions refer to the assembly and installation of a new heater, they should be retained by the installer; not left behind for the user as this would invite the dismantling and servicing by unqualified persons. FOR THE USER, there is a separate instruction leaflet explaining how the heater should best be operated. Please see that this leaflet is left with the heater for the user's purposes. THE HEATER MUST BE CONNECTED TO THE FIXED WIRING V!A A DOUBLE POLE ISOLATING SWITCH HAVING A CONTACT SEPARATION OF 3MM IN ALL POLES AND IN ACCORDANCE WITH THE I.E.E. REGULATIONS CURRENTLY IN FORCE AND IN ACCORDANCE WITH ANY LOCAL CODE OF PRACTICE, THE INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT ELECTRICIAN. CABLE HAVING A MINIMUM T RATING OF 85°C MUST BE USED. Heaters forming part of a comprehensive space heating system should be wired with their own separate circuit, if however, 1 or 2 heaters are installed as a starter system these may be connected to a 30 amp ring main provided that the instructions below are observed, any further heaters installed must be connected by its own circuit. If connected to a 30 amp ring circuit the total rating of heaters connected must not exceed 3kW, where the circuit supplies a kitchen, or 4kW, where the circuit does not include a kitchen. The storage radiator is designed to run on cheap overnight electricity, therefore the means of connecting the heater to the ring main should include a timer. These should be connected to the supply with 3 core heat resistant cable, the size of which is dependant on heater loading i.e. loading up to 10 amps use 1 mm", up to 13 amps use 1,5mm" and for the larger heaters 2.5mm" cable, WARNINGS - THIS APPLIANCE MUST BE EARTHED - SPECIAL ATTENTION MUST BE PAID TO THE SECURITY OF THE HEATER'S WALL FIXINGS. THE HEATER MUST BE PLACED ON A LEVEL SURFACE AVOIDING ANY IRREGULARITIES. Two supplies are taken into this heater, both fan heater and storage heater circuits must be connected to the same phase of the electricity supply. IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN IDENTICAL PART WALL FIXING: The heater must ALWAYS be mounted against, and fixed to a wall as it will not stand up by itself. A detachable bracket is provided for screwing to the wall, the heater is then placed in position and fixed to the bracket by a screw at each end. The heater must never be unscrewed or moved from the wall bracket whilst it is loaded with bricks. THE HEATER IS VERY HEAVY AND WILL BE DANGEROUS IF ITS WALL FIXING BECOMES INS...
Эта инструкция также подходит к моделям:Вентиляторы - 75772002S (635.77 kb)
Вентиляторы - 75772003S (635.77 kb)
Вентиляторы - 793485 (635.77 kb)
Вентиляторы - 793585 (635.77 kb)