Инструкция по эксплуатации Dimplex, модель FXL18N

Производитель: Dimplex
Размер: 162.85 kb
Название файла: dbbddd44-348c-4ddd-9fcc-481360ff2aca.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• A means for disconnection must be incorporated in the fixed wiring by a double pole switch with a contact separation of a minimum of 3mm and in accordance with the current IEE Wiring Regulations. • The heater must not be installed immediately below a fixed socket outlet. • The heater is not suitable for connection to a 30A ring circuit. • Do not position the heater under windows where curtains can contact the heater casing. • WARNING - THE SURFACES ON THIS HEATER CAN BE HOT. • This heater meets EN60335 safety requirements. However, any heater type becomes hot in normal operation. Care must be taken to ensure that prolonged skin contact with the heater does not occur. • WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice. • This appliance is very heavy and must be securely fixed to a wall. DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE. • To maintain stability, it is essential that the heater is placed on a level surface. • This heater must be installed where it is impossible for switches and other controls to be touched by a person using a bath or shower. • IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the first few days of operation. ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS, OR PERSONS WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD. • IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN IDENTICAL PART. INSTALLATION INSTRUCTIONS FAN/BOOST CIRCUIT STORAGE CIRCUIT PREPARATION The heater will arrive separately from its storage bricks, the following bricks will be required. FXL18N - 12 bricks FXL24N - 16 bricks WARNING - This appliance must be earthed Only heat resisting cable (min. rating T85) should be used. The wires in the mains cable will be coloured as follows:- GREEN & YELLOW - EARTH BLUE - NEUTRAL BROWN - LIVE SUGGESTED FIXINGS SOLID BRICK/BLOCK No. 10 Rawlplug fibre inserts, 5.5mm drill bit. Drill hole 10mm deeper than rawlplug length. PLASTERBOARD If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5 rawlplug intersets are suitable. NOTE: FOR OTHER WALL TYPES (e.g. timberframe and hollow concrete) SEEK SPECIALIST ADVICE. INSTALLATION 2. Remove the inner front panel by unscrewing the screws along its top and sides. As the front insulation is attached care must be taken when lifting this panel from the heater and placing it to one side. Remove the three inner guards by removing the screws along their bottom edges and sliding the guards up and off the base tray. Please note the location of each guard. 3. CONNECTION OF THE MAINS CABLE - Connect the restricted (E7) supply to the terminal block, marked “Storage Circuit”, having first passed the cable through a front cable clamp in the base. Connect the unrestricted (Peak) supply to the terminal block, marked “Fan/Boost Circuit”, having passed this cable through another cable clamp in the base. At this point, if desired, an external fan/boost timer may be fitted to the heater by passing the two wires from the timer through the remaining cable clamp, and connecting them across the terminal block, marked “Timer”, having already removed the link fitted across this block at the factory. Connect the EARTH lead from both supplies to the terminal marked with the symbol INSTALLATION INSTRUCTIONS FAN/BOOST CIRCUIT STORAGE CIRCUIT PREPARATION The heater will arrive separately from its storage bricks, the following bricks will be required. FXL18N - 12 bricks FXL24N - 16 bricks WARNING - This appliance must be earthed Only heat resisting cable (min. rating T85) should be used. The wires in the mains cable will be coloured as follows:- GREEN & YELLOW - EARTH BLUE - NEUTRAL BROWN - LIVE SUGGESTED FIXINGS SOLID BRICK/BLOCK No. 10 Rawlplug fibre inserts, 5.5mm drill bit. Drill hole 10mm deeper than rawlplug length. PLASTERBOARD If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5 rawlplug intersets are suitable. NOTE: FOR OTHER WALL TYPES (e.g. timberframe and hollow concrete) SEEK SPECIALIST ADVICE. INSTALLATION 2. Remove the inner front panel by unscrewing the screws along its top and sides. As the front insulation is attached care must be taken when lifting this panel from the heater and placing it to one side. Remove the three inner guards by removing the screws along their bottom edges and sliding the guards up and off the base tray. Please note the location of each guard. 3. CONNECTION OF THE MAINS CABLE - Connect the restricted (E7) supply to the terminal block, marked “Storage Circuit”, having first passed the cable through a front cable clamp in the base. Connect the unrestric...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории