Фрагмент инструкции


DCH 253 900 C PREMIUM STAINLESS STEEL EXTRACTOR HOOD WITH CURVED GLASS. PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING. The manufacturer strives for continuous improvements. For this reason, the text and illustrations in this book are subject to change without notice. Part Number 066471. INDEX 2 Description. 2 Before use. 2 Safety advice. 2 Electrical connection. 3 Preparing for installation. 3 Re-circulating filtered air. 3 Venting air to the outside. 4 Installation. 5 Grease filter. 5 Optional Carbon pad filter. 6 Operation. 6 Replacing the light bulbs. 7 Maintenance and cleaning. 7 Owner’s responsibility. 8 Service. 8 Warranty. 900 C PREMIUM EXTRACTOR HOOD You can rely on Defy OWNER’S MANUAL. DCH 253 900 C PREMIUM STAINLESS STEEL EXTRACTOR HOOD WITH CURVED GLASS. PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING. The manufacturer strives for continuous improvements. For this reason, the text and illustrations in this book are subject to change without notice. Part Number 066471. INDEX 2 Description. 2 Before use. 2 Safety advice. 2 Electrical connection. 3 Preparing for installation. 3 Re-circulating filtered air. 3 Venting air to the outside. 4 Installation. 5 Grease filter. 5 Optional Carbon pad filter. 6 Operation. 6 Replacing the light bulbs. 7 Maintenance and cleaning. 7 Owner’s responsibility. 8 Service. 8 Warranty. 900 C PREMIUM EXTRACTOR HOOD Description. Description. • The extractor hood fan extracts the kitchen vapours and passes them through the grease filter. • The grease filter absorbs the solid particles in the cooking vapours, keeping the kitchen almost free of grease. Before use. Before using your new extractor hood for the first time, please read this manual carefully. It contains important information concerning your personal safety as well as on the use and care of the extractor hood. • Remove all packaging (except the protective film on the two chimney sections) and dispose of it in an environmentally friendly manner. • If the extractor hood is damaged in any way, do not use it. Report the damage to your dealer, who will take the necessary corrective action. (Refer to Owner’s responsibility on page 8 of this manual). Safety advice. • This extractor hood complies with all relevant safety regulations. • The extractor hood is not intended for use by young children or infirm persons without supervision. Page 2 • Never operate the extractor hood without a grease filter. • Never leave cooking fat or oil unattended. Overheated fat or oil can easily catch fire. • Do not flambe food directly under the extractor hood. The flames pose the risk of the grease filter catching fire. (see page 7 under maintenance and cleaning) • Restrictions apply to the use of the extractor hood over a solid fuel or gas stove. (See Preparing for installation on page 3). • Switch off the power at the mains in the event of a fault or when cleaning the extractor hood • Do not touch any part of the light fittings while they are in use as they get very hot and could cause severe burns. Electrical connection. • The extractor hood uses a 220250V/ 50Hz power supply. • If the mains power cord is damaged, it must be replaced by a qualified electrician. • The power cord is located in the chimney area. Should you require an installation with no visible wiring, a 15 amp earthed plug socket should be accessible either in the ceiling above the extractor hood or on the wall behind the chimney area. (A qualified electrician should provide this facility). • The extractor hood must be earthed. The manufacturer and the seller do not accept responsibility for any damage due to incorrect electrical connection. • This extractor may not be used with a battery inverter power supply. Preparing for installation. Preparing for installation. The extractor hood has the ability to either recirculate the filtered air back into the kitchen, or to vent the filtered air through an outside wall. Decide on which option best suits you before commencing with the installation. • The extractor hood is intended to be mounted onto a flat perpendicular kitchen wall capable of supporting the weight of the hood. (approximately 26 kg.) Tools required for installation: • An electric drill. • A 3.5 mm dia. steel drill bit. • 8mm and 5mm dia. masonry drill bits • A star screw driver (Posi bit 2). • A ratchet with a 10mm socket and a 100mm extension. • A tape measure, masking tape and a pencil. ITEM DESCRIPTION QUANTITY 8mm wall plug 6mm screw 2 5mm wall plug 5mm screw 6 Self tapping screw 10 Slotted washer 2 Re-circulating filtered air. The extractor hood filters out solid particles before the air is re-circulated, via the vents on the side of the upper chimney, into the kitchen. Care must be taken during installation not to obstruct these vents. No ducting is required for this type of installation. Venting air to the outside. When discharging the air into a ventilation shaft or directly through the wa...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории