|
Фрагмент инструкции
Four-wire power supply must be used and the appliance wiring must be revised. See “Electrical requirements.” Copies of the standards listed may be obtained from: + National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269 For the most efficient and quiet operation: Fire Hazard q The size of the ductwork should be uniform. q The length of ductwork and number of elbows Terminate venting system to outside. should be kept to a minimum to provide efficient Use no more than three 90” elbows. l l q Do Not terminate the vent in an attic or other performance. enclosed space. q Make sure there is a minimum of 24 inches of q If roof or wall cap has a damper, Do Not use Use only metal ductwork. straight duct between the elbows if more than l one damper supplied with the range hood. l Do Not use 4” laundry-type wall caps. elbow is used. ~l Do Not obstruct the flow of combustion and q Use duct tape to seal all joints in the ductwork ventilation air. q Do Not install two elbows together. system. Failure to follow these instructions could result in a fire. q Ducting should transition to 9’ round duct as soon q Use caulking to seal exterior wall or roof as possible. opening around the cap. q 9’ round ducting is recommended for remote Determine which venting method is best for your blowers. application and follow “Installation steps” starting on Page 4. Property Damage l Before making cutouts, make sure there is proper clearance within the wall or floor for the exhaust duct. l Do Not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed. Failure to follow these instructions may result in property damage. Venting methods This range hood can be installed as either ducted or ductless. Ductwork needed for installation is not included. Vertical roof venting Horizontal wall venting 3-l/4” x IO” rectangular, 7” round, 8” round or 9” round ducting may be used. Ductwork can terminate either through the roof or wall. To vent through a wall, a 90” elbow is needed. The ductwork length should not exceed the lengths shown in the chart below. Duct size Maximum length 3-l/4’ x 10’ 35 feet 7’ round 40 feet 8’ round 50 feet 9’ round 60 feet Ductless installations vent out the grates in the sides of the chimney. Ductless installations require a Ductless Installation Kit, (Part Nos: 4378620 almond, 4378621 stainless steel, 4378622 white), available from your KitchenAid dealer. Calculating the ductwork length To calculate the length of the system you need, add the equivalent feet for each ductwork piece used in the system. 3-l/4” x 10” ductwork system Ductwork Piece 3-W’ x 10” Rectangular 7”, 8” or 9” Round 45” elbow 7.0 feet .$s::.... ..&!:;;.. 3-l/4” x .A...::::..:. 2.5 feet ...sssky. .:_ ~~:+.:‘.~:::. 10” elbow ..:...- ...&f >..,.::::.. 62..::::::::::::::*z s:.,..:::, . ...............<. ,:2$7 w wall -.-. ...... ..... cap .$:.... . .........>A ..:::z:.. 90” elbow 5.0 feet ..<::::<<::*:p 5.0 feet I ..;.:.:.:......:~::<~;:y.” ‘..:a::::.. “1-‘I;:.. _.<.’;:.s:.::;. ./A:.: F i &A::::::::::;;; .:.-.-. .......-. ..... :....... @,,:~.~~:~~~:~~~~:::.:~ ::. I. ..... .-....... ,.:.:.:.:.:.. -:I@ 2 ft. Maximum length = 35 feet 90” flat elbow 12.0 feet 1 -90” elbow = 5ft. ::...>::; ;gz:i.,.,‘.::..:., . ...... 8 feet straight = 8ft. :.~.~~~::~::.:..:,::::+.~;g$$ -1 ‘X :~~~~~~~~. .................. 1 -wall cap = oft. _ Length of ;;.;.. 3-l/4’ x 10’ system = 13ft. transition to round 5.0 feet ,... ..... ,-.---.>>:.>: . ........ . ...... . .... ..:.._ i .-. - -=o_ Note: Flexible ductwork is Not recommended. :.............. . ...... If it is used, each foot of flexible ductwork used is wall cap 0.0 feet ,&+ equivalent to two feet of straight metal ductwork ~~~~.g$< . ............ when calculating the ductwork length. (Example: @ ‘; ..;’ .:::::::::::::::::::::, _ . ............... A flexible elbow equals two standard elbows.) -. Page 2 Electrical Shock Hazard l Electrical ground is required on this appliance. l Do Not ground to a gas pipe. l Do Not have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock. l Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded. Failure to follow these instructions could result in serious injury or death. If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate. q A 120~volt, 60-Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both sides of the line. q A time-delay fuse or circuit breaker is recommended. q CONNECT WITH COPPER WIRE ONLY. q Connect directly to the fused disconnect (or circuit breaker box) through flexible, armored or non-metallic sheathed, copper cable (with grounding wire). q A U.L.-listed conduit connector must be used at each end of the power supply cable. q Allow some slac...
Эта инструкция также подходит к моделям:Вентиляторы - 883297 (785.76 kb)