Инструкция по эксплуатации KitchenAid, модель 42

Производитель: KitchenAid
Размер: 713.79 kb
Название файла: 10683eba-d9de-49de-a30d-723a29881152.pdf
Язык инструкции:enfr
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


Phillips screwdriver flat-blade screwdriver caulking gun and weatherproof caulking compound duct tape metal snips saber or keyhole saw Cabinet dimensionsProduct dimensions 12-1/32" (30.6 cm) 12" (30.5 cm) 18-3/16" (46.2 cm) 36" (91.4 cm) hood: 35-7/8" (91.1 cm) 42" (106.7 cm) hood: 41-7/8" (106.4 cm) 48" (121.9 cm) hood: 47-7/8" (121.6 cm) 25-3/16" (64 cm) 2-7/32" (5.6 cm) vent cover (if used) 1-3/8" (3.5 cm) 36" (91.4 cm) base cabinet height 36" (91.4 cm) hood: 36" (91.4 cm) 42" (106.7 cm) hood: 42" (106.7 cm) 48" (121.9 cm) hood: 48" (121.9 cm) min. cabinet opening widths 30" (76.2 cm) min. bottom of canopy to cooking surface canopy 13" (33 cm) cabinet depth 18" (45.7 cm) min. clearance upper cabinet to countertop Venting requirements Vent system must terminate to the outside. Do not terminate the vent system in an attic or other enclosed area. Do not use 4-inch (10.2 cm) laundry-type wall caps. Use metal vent only. Rigid metal vent is recommended. Do not use plastic or metal foil vent. For the most efficient and quiet operation: • The size of the vent should be uniform. • Use no more than three 90° elbows. • Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than one elbow is used. • Do Not install two elbows together. • The length of vent system and number of elbows should be kept to a minimum to provide efficient performance. • The vent system must have a damper. If roof or wall cap has a damper, Do Not use damper supplied with the range hood. • Use duct tape to seal all joints in the vent system. • Use caulking to seal exterior wall or roof opening around the cap. Determine which venting method is best for your application and follow “Preparation” under ”Installation steps“ on Page 5. For installations with canopy only, minimum of 84-3/16" (213.8 cm). For installations with optional vent hood cover, minimum of 96-3/16" (244.3 cm). Ceiling height above canopy or canopy with optional vent hood is unlimited. Venting methods This canopy range hood is factory set for vertical venting. For rear vent applications, the blower must be turned inside the range hood so that the blower vents to the rear as indicated. The blower is turned by removing two screws on each side of the blower, rotating the blower with the exhaust opening facing the rear and then replacing the screws. The exhaust cover(s) must be moved to block the unused opening(s). The blower must be converted before installing the range hood. Vent system needed for installation is not included. The 36" (91.4 cm) and 42" (106.7 cm) models have one exhaust opening. 3-1/4" x 10" (8.3 cm x 25 cm) rectangular, 7" (17.8 cm) round, 8" (20.3 cm) round, 9" (22.9 cm) round, or 10" (25.4 cm) round vent may be used. The hood exhaust opening is 3-1/4" x 10" (8.3 cm x 25 cm). The 48" (121.9 cm) model has two 3-1/4" x 10" (8.3 cm x 25 cm) exhaust openings. It is recommended that Vent Transition Kit No. 8284757 be used to transition the two openings into one 10" (25.4 cm) round vent. (Cannot be used with Chimney Extension Kit No. 8284754.) Vent system can terminate either through the roof or wall. The vent system length should not exceed the lengths shown in the chart. Vertical venting Horizontal venting roof cap 3-1/4" x 10" (8.3 cm x 25 cm) vertical venting (roof or wall) 3-1/4" x 10" (8.3 cm x 25 cm) horizontal venting wall cap Vent size Maximum length 3-1/4" x 10" (8.3 cm x 25 cm) 35 ft. (10.7 m) 7" (17.8 cm) round 40 ft. (12.2 m) 8" (20.3 cm) round 50 ft. (15.2 m) 9" (22.9 cm) round 60 ft. (18.3 m) 10" (25.4 cm) round 60 ft. (18.3 m) Calculating the vent system length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. Vent Piece 3-1/4" x 10" (8.3 cm x 25 cm) Rectangular 7" (17.8 cm), 8" (20.3 cm), 9" (22.9 cm), 10" (25.4 cm) Round 45° elbow 7.0 feet (2.1 m) 2.5 feet (0.8 m) 90° elbow 5.0 feet (1.5 m) 5.0 feet (1.5 m) 90° flat elbow 12.0 feet (3.7 m) transition to round 5.0 feet (1.5 m) wall cap 0.0 feet (0.0 m) Example for 3-1/4" x 10" (8.3 cm x 25 cm) vent system 3-1/4" x 10” wall (8.3 cm x 25 cm) cap elbow 6 ft. (1.8 m) 2 ft. (0.6 m) Maximum length = 35 ft. (10.7 m) 1 — 90° elbow = 5 ft. (1.5 m) 8 ft. (2.4 m) straight = 8 ft. (2.4 m) 1 — wall cap = 0 ft. (0 m) Length of 3-1/4" x 10" (8.3 cm x 25 cm) system = 13 ft. (4 m) Note: Flexible vent is Not recommended. Flexible vent creates back pressure and air turbulence that greatly reduces performance. Electrical requirements Important: Observe all governing codes and ordinances. It is the customer’s responsibility: •To contact a qualified electrical installer. •To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qu...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории