|
Фрагмент инструкции
However a detailed visual inspection should reveal evidence of burning around the fault. Ignition System / Gas Ignition Ignition System / Gas IgnitionIgnition System / Gas IgnitionIgnition System / Gas IgnitionIgnition System / Gas IgnitionIgnition System / Gas Ignition Ignitor does not spark NO NONONONONO YES YESYESYESYESYES Check gas supply at burner Check plug top fuse and replace if necessary Light burner manually Check polarity and earth continuity of supply point Check by pass simmer adjusted Check earth continuity of appliance Check position of the electrode Check fitting of burners Check continuity from 'N' on the mains connector block and "O" on the ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check continuity from 'L' on the mains connector block and the taps ignition switches Check for breaks in the insulation of the HT leads Check continuity from ignition switches connector to ignitor unit Change the ignitor unit Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below. • .. 1) Turn the gas tap to the MAX position and ignite. 2) Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below. Procedure: Procedure:Procedure:Procedure:Procedure:Procedure: • .. 1) Re-ignite the burner and set to MIN. 2) Remove the control knob. 3) To adjust, use a thin bladed screwdriver and turn the adjustment screw (see diagram) until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for all burners. Pr PrPrPrPrPressur essuressuressuressuressure T e Te Te Te Te Testing estingestingestingestingesting The pressure testing must be carried out on the burners. • .. Proceed as follows: 1) Remove the pan supports and the burner caps and crowns. 2) Fit manometer tube over the injector. 3) Turn on the burner gas supply and ignite another burner supply. The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar. 4) Turn off the burner supplies. Minimum adjustment Minimum adjustmentMinimum adjustmentMinimum adjustmentMinimum adjustmentMinimum adjustment screw screwscrewscrewscrewscrew Conversion from Natural Gas to LPG IMPOR IMPORIMPORIMPORIMPORIMPORT TTTTTANT ANTANTANTANTANT The replacement/conversion from natural gas to LPG should only The replacement/conversion from natural gas to LPG should onlyThe replacement/conversion from natural gas to LPG should onlyThe replacement/conversion from natural gas to LPG should onlyThe replacement/conversion from natural gas to LPG should onlyThe replacement/conversion from natural gas to LPG should only be undertaken by a competent person. be undertaken by a competent person.be undertaken by a competent person.be undertaken by a competent person.be undertaken by a competent person.be undertaken by a competent person. It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. The gas rate is adjusted to suit. Method MethodMethodMethodMethodMethod • .. 1) Ensure that the gas taps are in the 'OFF' position 2) Isolate the hob from the electricity supply 3) Remove all pan supports, burner caps, rings, crowns and control knobs. 4) With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors. TO ADJUST THE GAS RA TO ADJUST THE GAS RATO ADJUST THE GAS RATO ADJUST THE GAS RATO ADJUST THE GAS RATO ADJUST THE GAS RATE TETETETETE With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw. Upon completion stick the replacement rating plate on the under side of the hob. Guarantee/Customer Service Standard guarantee conditions Standard guarantee conditionsStandard guarantee conditionsStandard guarantee conditionsStandard guarantee conditionsStandard guarantee conditions We, Zanussi-Electrolux, undertake that if within 12 months of the date of the purchase this Zanussi-Electrolux appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, we will, at our option repair or replace the same FREE OF CHARGE for labour, materials or carriage on condition that: · The appliance has been correctly installed and used only on the electricity supply stated on the rating plate. · The appliance has been used for normal domestic purposes only, and in accordance with the manufacturer’s instructions. · The appliance has not been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by us. · Electrolux Service Force Centre must undertake all service work under this guarantee. · Any appliance or defective part replaced shall become the Company’s property. · This guarantee is in addition...
Эта инструкция также подходит к моделям:Варочные панели - ZGS 782 ICT (579.13 kb)
Варочные панели - ZGS 782 ICT (579.13 kb)
Варочные панели - ZGS 782 IT (579.13 kb)
Варочные панели - ZGS 782 IT (579.13 kb)