Войти:
Оценок - 5, средний балл: 4.2 ( )

Инструкция по эксплуатации Hotpoint, модель COOKER AND OVEN

Производитель: Hotpoint
Размер: 277.05 kb
Название файла: EG902GX_19506022000.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


! Please keep these operating instructions for future reference. Make sure that the instructions are kept with the appliance if it is sold, given away or moved. ! The appliance must be installed by a qualified professional according to the instructions provided. ! Any necessary adjustment or maintenance must be performed after the cooker has been disconnected from the electricity supply. Room ventilation The appliance may only be installed in permanently- ventilated rooms, in accordance with current national legislation. The room in which the appliance is installed must be ventilated adequately so as to provide as much air as is needed by the normal gas combustion process (the flow of air must not be lower than 2 m3/h per kW of installed power). The air inlets, protected by grilles, should have a duct with an inner cross section of at least 100 cm2 and should be positioned so that they are not liable to even partial obstruction (see figure A). These inlets should be enlarged by 100% - with a minimum of 200 cm2 - whenever the surface of the hob is not equipped with a flame failure safety device. When the flow of air is provided in an indirect manner from adjacent rooms (see figure B), provided that these are not communal parts of a building, areas with increased fire hazards or bedrooms, the inlets should be fitted with a ventilation duct leading outside as described above. Adjacent room Room requiring ventilation A B A Ventilation opening Increase in the gap between for comburent air the door and the flooring ! After prolonged use of the appliance, it is advisable to open a window or increase the speed of any fans used. Disposing of combustion fumes The disposal of combustion fumes should be guaranteed using a hood connected to a safe and efficient natural suction chimney, or using an electric fan that begins to operate automatically every time the appliance is switched on (see figure). Fumes channeled outside Fumes channelled through straight a chimney or a branched flue system (reserved for cooking appliances) ! The liquefied petroleum gases are heavier than air and collect by the floor, therefore all rooms containing LPG cylinders must have openings leading outside so that any leaked gas can escape easily. LPG cylinders, therefore, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc.). Only the cylinder being used should be stored in the room; this should also be kept well away from sources of heat (ovens, chimneys, stoves) that may cause the temperature of the cylinder to rise above 50°C. Positioning and levelling ! It is possible to install the appliance alongside cupboards whose height does not exceed that of the hob surface. ! Make sure that the wall in contact with the back of the appliance is made from a non-flammable, heat- resistant material (T 90°C). To install the appliance correctly: • Place it in the kitchen, the dining room or the bed- sit (not in the bathroom). • If the top of the hob is higher than the cupboards, the appliance must be installed at least 600 mm away from them. • If the cooker is installed underneath a wall cabinet, there must be a minimum distance of 420 mm between this cabinet and the top of the hob. This distance should be increased to 700 mm if the wall cabinets are flammable (see figure). 2 HOOD 900Min. mm. 420Min.min. 650 mm. with hoodmin. 700 mm. without hoodmm. 420Min. mm. • Do not position blinds behind the cooker or less than 200 mm away from its sides. • Any hoods must be installed according to the instructions listed in the relevant operating manual. Levelling If it is necessary to level the appliance, screw the adjustable feet into the places provided on each corner of the base of the cooker (see figure). The legs* fit into the slots on the underside of the base of the cooker. Electrical connection WARNING – THIS APPLIANCE MUST BE EARTHED. The appliance is designed to work with alternating current at the supply voltage and frequency indicated on the rating plate (situated on the rear part of the appliance and on the last page of the instruction booklet) or at the end of the instruction booklet. Make sure that the local supply voltage corresponds to the voltage indicated on the rating plate. To connect directly to the mains supply, a double- pole switch with a contact separation of at least 3 mm suitable for the load and complying with current standards and regulations, must be fitted between the appliance and the mains supply outlet. The yellow-green earth wire must not be interrupted by the switch. The supply cable must be in such a position that no part of it can reach a temperature of 50 °C above room temperature. Do not use adapters or shunts as they could cause heating or burning. Before connecting to the power supply, make sure that: • the limiter valve and the domestic system can withstand the load from the appliance (see rating GB plate); • the supply system is efficien...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории