Войти:
Оценок - 4, средний балл: 4.8 ( )

Инструкция по эксплуатации DCS, модель 35600G

Производитель: DCS
Размер: 177.42 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


* Your new home is within the European Community (EC) or European Free Trade Area. * The product is installed and used in accordance with our instructions and is only used domestically, i.e. a normal household * The electrical supply complies with the specification given in the rating label. * The product is installed taking into account regulations in your new country. Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0)3 44 62 29 29 Germany Nurnberg +49 (0)911 323 2600 Italy Pordenone +39 (0)1678 47053 Sweden Stockholm +46 (0)8 738 7910 UK Slough +44 (0)1753 219899 Instructions for the Installer Engineers technical data OVERALL DIMENSIONS Width: Depth: Height: Weight: 580 mm. 500 mm. 88 mm. 8 Kg. CUT OUT DIMENSIONS Width: Depth: Thickness: 550 mm. 470 mm. 30 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. IGNITION HT SPARK Spark Generator Ispra Control's BF 50046 - 230-240V 0.6 YA T120 Spark Gap : Fixed HEAT INPUT Rear Left Burner 2.0 kW (6824 BTU/HR) (semi rapid) Front Left Burner 3.0 kW Natural Gas (10236 BTU/HR) (rapid) 2.8 kW L.P.G. (9554 BTU/HR) Rear Right Burner 2.0 kW (6824 BTU/HR) (semi rapid) Front Right Burner 1.0 kW (3412 BTU/HR) (auxiliary) APPLIANCE CLASS 3 APPLIANCE CATEGORY II2H3+ GAS SUPPLY Natural gas G20 / 20mbar BURNER RAPID SEMI-RAPID AUXILIARY (large) (medium) (small) TYPE OF GAS POSITION MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW 3.0 0.65 2.0 0.45 1.0 0.33 NATURAL GAS 20 mbar NOMINAL FLOW VALUE = RATE m3/h 0.286 0.057 0.190 0.038 0.095 0.028 37.78 MJ/m3 NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust. Ws - 50.7 MJ/ m3 1/100 mm NOMINAL THERMAL LPG GAS POWER kW 2.8 0.65 2.0 0.45 1.0 0.33 28-30/37 mbar NOMINAL FLOW VALUE = RATE g/h 202 43.5 144 29 72 21,5 49.92 MJ/Kg NOZZLE REFERENCE 86 40 71 32 50 28 1/100 mm Burner Dia. Tap By-pass Tap colour 1/100 mm Auxiliary 28 Red/Red Semi-rapid 32 Blue/Blue Rapid 40 Black/Black Aeration adjustment none Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the...

Эта инструкция также подходит к моделям:
Варочные панели - 34602G (177.42 kb)
Варочные панели - 34611C (177.42 kb)
Варочные панели - 34611C (177.42 kb)
Варочные панели - 35604G (177.42 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории