Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации AEG, модель 34942G

Производитель: AEG
Размер: 110.63 kb
Название файла: 714102EN.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Depth: 500 mm. Height: 88 mm. Weight: 8 Kg. CUT OUT DIMENSIONS Width: 830 mm. Depth: 470 mm. Thickness: 30 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. IGNITION HT SPARK Spark Generator Ispra Control's BF 50066 - 230-240V 0.6 YA T120 Spark Gap : Fixed HEAT INPUT Rear Left Burner (semi rapid) 2.0 kW (6824 BTU/HR) Front Left Burner (rapid) 3.0 kW Natural Gas (10236 BTU/HR) 2.8 kW L.P.G. (9554 BTU/HR) Central Burner (double-crown) 3,5 kW (11942 BTU/HR) Rear Right Burner (semi rapid) 2.0 kW (6824 BTU/HR) Front Right Burner (auxiliary) 1.0 kW (3412 BTU/HR) APPLIANCE CLASS 3 APPLIANCE CATEGORY II2H3+ GAS SUPPLY Natural gas G20 / 20mbar BURNER RAPID SEMI-RAPID AUXILIARY DOUBLE (large) (medium) (small) CROWN TYPE OF GAS POSITION MAX MIN MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW 3.0 0.65 2.0 0.45 1.0 0.33 3.5 1.2 NATURAL GAS 20 mbar NOMINAL FLOW VALUE = RATE m3/h 0.286 0.057 0.190 0.038 0.095 0.028 0.333 0.114 37.78 MJ/m3 NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust. 136 Adjust. Ws - 50.7 MJ/ m3 1/100 mm NOMINAL THERMAL LPG GAS POWER kW 2.8 0.65 2.0 0.45 1.0 0.33 3.5 1.2 28-30/37 mbar NOMINAL FLOW VALUE = RATE g/h 202 43.5 144 29 72 21,5 252 86 49.92 MJ/Kg NOZZLE REFERENCE 86 40 71 32 50 28 93 56 1/100 mm Burner Dia. Tap By-pass Tap colour 1/100 mm Auxiliary 28 Red/Red Semi-rapid 32 Blue/Blue Rapid 40 Black/Black Double-Crown 56 Black/Red Aeration adjustment none Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm. between the rear edge of the hob and the wall. A minimum distance of 100 mm. must be left between the side edges of the hob and any adjacent cabinets or walls. The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm. If it is fitted below 400 mm. a space of 50 mm. must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITH A COOKER HOOD ABOVE 700 mm 400 mm 100 mm 400 mm 50 mm 50 mm 55 mm 400 mm 400 mm 100 mm 50 mm 50 mm 55 mm FO 2027* FO 2028* 700 mm CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITH A COOKER HOOD ABOVE 700 mm 400 mm 100 mm 400 mm 50 mm 50 mm 55 mm 400 mm 400 mm 100 mm 50 mm 50 mm 55 mm FO 2027* FO 2028* 700 mm Installation IMPORTANT This hob must be installed by qualified personnel to the relevant British Standards. Any gas installation must be carried out by a CORGI registered installer. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in Installation FO 0814 FO 0264 A) End of shaft with nut B) Washer C) Elbow this book be ignored. On the end of the shaft, which includes the GJ 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force. Gas Connection Connection to the gas supply should be with either rigid or semi-rigid pipe, i.e. steel or copper. The connection should be suitable for connecting to RC 1/2 (1/2 BSP male thread). When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. Ensure that the main connection pipe does not exert any strain on the hob. It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe. Failure to ensure the correct assembly will cause leakage of gas. Cut Out Size The dimensions of the cut-out are g...

Эта инструкция также подходит к моделям:
Варочные панели - 34942G (110.63 kb)
Варочные панели - 34942G (110.63 kb)
Варочные панели - 34942G (110.63 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории