Войти:
Оценок - 3, средний балл: 5 ( )

Инструкция по эксплуатации Bionaire, модель BCM630CN05EFM1

Производитель: Bionaire
Размер: 99.6 kb
Название файла: BCM630-CN_43_3190360.pdf
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


2. Within the first 24 months from date of purchase, JCS/THG, LLC will repair or replace the product if it is defective in material or workmanship, subject to the conditions in paragraph G. F. If you have any other problem or claim in connection with this product, please write to our Consumer Service Department. G. IMPORTANT RETURN INSTRUCTIONS. Your Warranty depends on your following these instructions if you are returning the unit to JCS/THG, LLC: 1. Carefully pack the item in its original carton or other suitable box to avoid damage in shipping. 2. Before packing your unit for return, be sure to enclose: a) Your name, full address with zip code and telephone number DIGITAL HUMIDISTAT INSTRUCTIONS To take advantage of the Digital Humidistat, press the MODE/OFF button until the speed is set in either the auto HIGH (A3), auto MEDIUM (A2) or auto LOW (A1) setting. Then adjust the set humidity by using the up and down buttons. Humidity will increase or decrease in increments of 5%. When the humidity level is set, the display will return to show the current room humidity. When the room humidity level rises above the set humidity, the humidifier will stop. When the humidity level drops below the set humidity, the humidifier will turn on automatically. NOTE: Allow up to 30 minutes for the filter to fully absorb water and for the unit to produce moisture. NOTE: The Digital Humidistat Humidifier has memory. This means that when you turn the unit back on, it will be at the last setting the humidifier was set at. If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water tank, base and wick filter to prevent algae or bacteria growth. EXTENDED RUN TIME SETTING By setting you humidifier to a specific humidity level, you are actually also extending the run time. Since the unit will turn on and off to maintain the set humidity level, less water will be used, so you will need to fill the unit less than you would on manual setting. USING THE PROGRAMMABLE TIMER Digital Humidistat allows the user to program the humidifier to come on at a preset time, or turn off after a set amount of time. SETTING THE OFF TIMER 1. Set the mode and/or humidity you wish the humidifier to run in. 2. While the humidifier is running, press and hold the up and down buttons simultaneously for 2 seconds. The display will flash “00”. 3. By pressing the up and down buttons, program the humidifier to turn off up to 16 hours later in increments of 1 hour. 4. After setting the timer, the display will return to show the current room humidity. The timer light will illuminate to show that the timer is activated. 5. After the predetermined length of time has passed, the humidifier will automatically shut off. b) A dated sales receipt or PROOF OF PURCHASE, c) Your $12.50 check for return shipping and handling, and d) The model number of the unit and the problem you are having. (Enclose in an envelope and tape directly to the unit before the box is sealed.) 3. JCS/THG, LLC recommends you ship the package U.P.S. ground service for tracking purposes. 4. All shipping charges must be prepaid by you. 5. Mark the outside of your package: Bionaire® JCS/THG, LLC 303 Nelson Avenue Neosho, MO 64850 SHIPPING AND HANDLING CHARGES: $12.50 (USD) This Warranty gives you specific legal rights, and you may have other rights which vary from state to state. The provisions of this Warranty are in addition to, and not a modification of, or subtraction from, the statutory warranties and other rights and remedies contained in any applicable legislation. To the extent that any provision of this Warranty is inconsistent with any applicable law, such provision shall be deemed voided or amended, as necessary, to comply with such law. © 2006 JCS/THG, LLC Bionaire®, the Bionaire logo® and Clean-Away™ are trademarks of JCS/THG, LLC. BCM630CN05EFM1 Printed In China Figure 1 F A. Tank E B. Tank Handle C. Base B D. Humidifier D Housing E. Control Panel F. Filter Monitor A C SETTING THE ON TIMER 1. While the humidifier is off, press and hold the up and down buttons simultaneously for 2 seconds. 2. By pressing the up and down buttons, program the humidifier to turn on up to 16 hours in advance in increments of 1 hour. 3. After the preset length of time has passed, the humidifier will automatically turn on Auto Mode HI at 45% for a preset time of 2 hours. REPLACING THE FILTERS Through normal use, waterborne minerals and sediment become trapped in the wick filters. The harder your water, the greater the amount of minerals in the water, and the more often you will be able to monitor the life of your filters in your humidifier. You will be able to monitor the life of the filters in your humidifier by checking the Filter Monitor Indicator. After 60 minutes of use, Filter Monitor Indicator will move and indicate your filters condition. New filters will register in the section reading GOOD filter. After frequent use of your humidifier, the Fi...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории