Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Bionaire, модель BCM646

Производитель: Bionaire
Размер: 234.17 kb
Название файла: 91627e5e-defb-4207-8ce4-4598e7b07dbc.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Please note that this is an electrical appliance and requires attention when in use. In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the water tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up. DAILY MAINTENANCE 1. Be sure the unit is OFF and is disconnected from the electrical outlet. 2. Remove the housing and the tank from the humidifier and place in sink or tub. 3. Carry the base of the unit to the sink, remove the wick, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean, and dry with a clean cloth or paper towel. 4. Drain the water from the tank into the sink and rinse tank thoroughly. Wipe clean, and dry with a clean cloth or paper towel. 5. Put filter back in, replace the housing, then refill tank with cool tap water as instructed earlier in the Filling Instructions. Do not overfill. 6. Follow Operating Instructions. WEEKLY MAINTENANCE To Remove Scale: 1. Repeat steps 1-4 above. 2. Clean the base by partially filling the base with one 8oz cup of undiluted white vinegar, or by using Clean AwayTM (Model DMS216) by the manufacturer. Leave this solution in the base for 20 minutes, while cleaning all interior surfaces with a soft brush. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar. 3. Rinse with clean warm water to remove the cleaning solution before disinfecting the tank. TO DISINFECT RESERVOIR 1. Fill humidifier reservoir 1/2 full with water and 1/2 tablespoon of chlorine bleach. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Carefully empty the reservoir after 20 minutes, and rinse with warm water until you can not detect any bleach smell. Dry with a clean cloth or paper towel. 4. Place filter back into reservoir and refill the water reservoir as directed in Operating Instructions, and turn the unit on. STORAGE INSTRUCTIONS When not using your humidifier for an extended period of time: 1. Dispose of the filters. DO NOT leave in unit. 2. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season. 3. Place the humidifier in the original carton and store in a cool, dry place. 4. Order your replacement filter for next year’s use. FILTER#: BWF100/HWF100 (2) Filter Type: Wick Read instructions before operating. Retain for future reference. Instruction Leaflet . INFO-LINE If after having read this leaflet, you have any questions or comments on your humidifier, call 1-800-253-2764 in North America. 127053/9100030004879 digital COOL MOISTURE humidifier MODEL: BCM646 TROUBLESHOOTING Trouble Solution Probable Cause • Unit does not turn on . Plug in Unit . Not plugged in • Mist output minimal . Wait 30 minutes for filter to . Filter has not absorbed to none absorb water water • Filter turns brown . Replace your filter (BWF100) minerals . The filter has absorbed by calling 1-800-253-2764 or visiting: . Takes 60 minutes to register • FilterCheck® is . Allow the humidifier to run not working continuously for 60 minutes for the FilterCheck® Indicator to reflect the filter condition . Continue to operate humidifier • Humidifier continuously . Humidity at the humidifier is to raise the room humidity displays 21% at or below 21% . Stop operating the humidifier . Humidity at the humidifier is • Humidifier continuously if the humidity level is too high at or above 90% displays 90% FREQUENTLY ASKED QUESTIONS Answer Question . The estimated run time for this humidifier is based on affect run time? • What are the variables that average room conditions. The actual run time of your humidifier is dependent on numerous variables such as: 1. Air exchange in the room where the humidifier is placed. 2. Room construction of the room where the humidifier is placed. 3. Temperature of the room where the humidifier is placed. 4. Humidity levels in the room where the humidifier is placed. 5. Movement of occupants and the opening and closing of doors in the room where the humidifier is placed. 6. Home furnishings in the room where the humidifier is placed. . See Daily Maintenance instructions. Regular cleaning is water tank? • How do I remove film on recommended. . Run your unit on the lowest setting. time? • How can I extend the run . If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time. . Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximu...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории