Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации Dimplex, модель WFC 3NS

Производитель: Dimplex
Размер: 284.46 kb
Название файла: a00b6521-0cfd-4b7b-9245-6446d606c5e7.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Do not use heater to dry your laundry. This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance. If young children, the aged, or infirm are likely to be left in the vicinity of the heater, we advise that adequate precautions should be taken. We recommend that a guard be fitted to ensure contact with the heater is avoided and objects cannot be inserted into the product. WARNING: In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.Do not use where excessive dust or moisture is present. For further information, please contact our guard supplier direct on Tel. No. 01603 667957, or in the case of difficulty or for further advice contact the Customer Helpline. Installation Before undertaking installation work, ensure the electricity supply is disconnected from any relevant fixed wiring. Supply cable is not provided with this appliance, and a competent electrician should therefore install it. The appliance must be fitted horizontally with the cable or conduit entry at bottom right. It should be mounted such that the underside is at least 350mm above the floor and the top of the heater is 150mm below any overhanging shelf or obstruction. This heater must be used on an A.C.~ supply only and the voltage marked on the heater must correspond to the supply voltage. To comply with the I.E.E. Wiring Regulations, the appliance must be earthed; the supply circuit must be adequate for the input of the appliance, and the circuit protected by a suitable 13A fuse. A suitable termination to the fixed wiring of the premises must be provided adjacent to the final position of the appliance. In this instance, such a termination can be a doublepole switch with a contact separation of at least 3mm in all poles. The heater must not be located immediately below a fixed socket-outlet. Electrical WARNING : THIS APPLIANCE MUST BE EARTHED. After ensuring the electricity supply is not live, electrical connections can be made, either to an adjacent double-pole switch having a contact separation of at least 3mm in all poles or to a plug-top for use in a standard 13A socket. If the latter: Connect Green and Yellow wire to plug terminal marked E or iii1 Green or Green and Yellow. Connect Blue wire to plug terminal marked N or Black. Connect Brown wire to plug terminal marked L or Red. Refit cover, first hooking top over the back of the unit and then securing the bottom by refitting the two screws under the bottom edge. The appliance is now ready for use and the electricity supply can be reinstated. Fixing dimensions Operation Procedure Release the front cover from the unit by undoing the two screws under the bottom edge. Carefully remove cover by pulling bottom-front forward, and then lift to release top from retaining slots. Mark screw fixing positions on wall in accordance with the dimensions shown on the diagram in Fig 2. The unit must be secured to the wall with four screws through the holes provided. The two upper holes are keyhole shaped to enable the two upper screws to be positioned first. The unit can then be hung on these screws while the two lower screws are positioned. Before finally tightening all four screws, ensure the unit is truly horizontal. Fit a 3 core 1.5 square millimetre flexible cord through the cable entry bush, connect wires to the appropriate terminals and tighten cable clamp. Alternatively the heater may be connected with conduit through the base after removing the knockout containing the cable entry bush (see Fig. 2). Wiring Diagram CAS LE CLAMP Fig. 4 - Controls & Control Panel Layout The Dimplex WFC 3NB and WFC 3NS have a total loading of 3Kw. They are fitted with two control knobs and a pilot light. The air inlet is in the front panel, and the outlet on the underside. The upper knob operates a six-position switch, giving a choice of operating characteristics as follows : o — Off 1 — 1Kw of heat, low fan speed. II — 2Kw of heat, medium fan speed III — 3Kw of heat, high fan speed. # — Fan only, low speed. — Fan only, high speed. The lower knob operates a thermostat which enables the temperature of the room to be regulated. The pilot light indicates when the appliance is connected to the electricity supply. Thermal Safety Cut-out In the event that the appliance overheats, the cut-out switches the heater off automatically. To bring the heater back into operation, remove the cause of overheating, then turn Off the electrical supply to the heater for a few minutes. When the heater has cooled sufficiently reconnect and switch On the heater. If the cut-out operates repeatedly, cont...

Эта инструкция также подходит к моделям:
Увлажнители воздуха - WFC 3NB (284.46 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории