Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Essick Air, модель 4D7 800

Производитель: Essick Air
Размер: 497.95 kb
Название файла: a1d55e71-c981-42f3-ade9-987f330ee45c.pdf
Язык инструкции:enesfr
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


To reduce the risk of electric shock, this plug is intended to fit into a polarized 120-volt AC, 15 amp outlet, and only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. If an extension cord must be used, it should also accept the wide blade plug and meet this electrical rating. 2. Do not place the cord under rugs, near loose draperies, in traffic areas, nor near heat sources or combustible materials. 3. Do not use the humidifier if the cord is damaged. 4. Always unplug the power cord before filling, cleaning, servicing, or when the unit is not in use. 5. This humidifier is ETL listed with Essick Air brand evaporative wicks in place. 6. It is very important that cleaning solutions such as bleach, anti-bacteria treatment or descaler, which could be used to clean the cabinet, are not sprayed or applied to the chassis assembly. These solutions can cause serious electrical malfunction of the humidifier. INTRODUCTION Your Essick Air evaporative humidifier adds invisible moisture to your home by moving dry air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is no messy mist or spray, just clean and invisible moist air. As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier's efficiency. Use only Essick Air brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1-800-547-3888. The 400 Series humidifiers use Essick Air wick # 1041 and accommodate optional air filter #1051. Only the Essick Air evaporative wick guarantees the certified output of your humidifier. Use of wicks other than Essick Air brand will void your warranty as well as the certification of output and may reduce the efficiency of your humidifier. CAUTION: Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on soft carpet. HOW YOUR HUMIDIFIER WORKS Dry air is drawn into the humidifier though the back and moisturized as it passes through the evaporative wick. It is then fanned out into the room. LEGEND: 1. Water bottle 2. Chassis/power pack (motor/fan assembly) Evaporative wick Water reservoir Dry room air intake Moist air output 2 ASSEMBLY UNPACKING AND SETTING UP THE UNIT 1. Remove the two inserts from the top of the humidifier. 2. Lift off the water bottle covers. Remove the water bottles, lift off the chassis/power pack and then remove the humidifier cabinet from the carton. 3. Remove the evaporative wick and all of the remaining packaging materials from the cabinet. Check to see that you have all of the following items removed from the boxes, accessory kit, and cabinet before discarding the packaging: ♦ Filler Hose ♦ Evaporative Wick ♦ Caster kit ♦ Two end covers ♦ Bacterial treatment sample ♦ Two Water Bottles CASTERS 4. Turn the empty cabinet upside down. Insert each caster stem into a caster hole on each corner of the humidifier bottom. The casters should fit snugly and be inserted until the stem shoulder reaches the cabinet surface. 5. Turn the cabinet right side up. EVAPORATIVE WICK 6. Insert the 1041 wick into the unit. The wick has a mounting rib on the top edge which hooks over a rib at the inside back of the cabinet. This allows the wick to hang in the water channel (see cutaway illustration for details). Hang wick into cabinet as shown. OPTIONAL AIR CLEANING FILTER (sold separately) 7. If available, install the 1051 AirCare® filter at the back of the unit. The filter has four tangs that engage into four keyhole slots that mount the AirCare® filter onto the outside of the back of the cabinet. FILLING INFORMATION 8. Your humidifier is equipped with two water bottles. Each bottle holds 2.75 gallons. 9. A fill hose that fits most faucets is provided with your humidifier. Fill the bottles with cool, fresh (preferably unsoftened) water. If you only have softened water available in your home, you can use it, but mineral buildup will occur more quickly. NOTE: For optimum running time, fill each water bottle, tighten the cap, and place inside unit. Do not fill the reservoir bucket, as overfilling will result in water damage. Use only the bottles provided. One bottle will drain until the reservoir is filled. Remove the partially emptied bottle and refill it. Place back in humidifier cabinet. 3 CAUTION: When filling, be careful not to pressurize the bottle by overfilling it. Bottle damage can result from this, and will not drain properly. NOTE: On initial fill up, it will take approximately 20 minutes for the reservoir to fill because the dry wick has...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории