К этому устройству также есть другие инструкции:
Фрагмент инструкции
Verify the contents
Installing the new power supply
Check the contents of the SN6000 Fibre Channel
1.
Confirm that the new power supply air flow
Switch power supply carton. The carton contains one
direction is compatible with the old power
power supply.
supply. The air flow direction is noted on the
part number label.
2.
With the AC receptacle on the right, slide the
Preparation
power supply into the bay until it is firmly
seated.
The power supplies are hot pluggable and
interchangeable. When removing or replacing a
3. Secure the knurled fasteners by hand.
power supply on an operating switch, be sure that the
4. Plug the power cord into the AC receptacle and
Heartbeat LED is flashing once per second. This
confirm that the air flow direction is correct.
indicates that the switch will continue operating
Figure 3 Installing the new power supply
normally while the power supply is being removed or
replaced.
Figure 1 Observing the Heartbeat LED
1
1
2
1 Heartbeat LED (green)
1 Part number label
2 AC receptacle
Removing the failed power supply
1.
Unplug the power cord from the power supply.
2.
Using a cross-head screwdriver, loosen the two
knurled fasteners.
3. Grasp the power supply handle and pull firmly
to disengage the modular connector.
4. Remove the power supply from the bay.
Figure 2 Removing the failed power supply
1
2
1
1 Knurled fastener
2 Handle
Page 2