Version: HP StorageWorks Clustered File System 3.6.1h1
Description
This hotfix resolves the issues described below. The hotfix also includes a new file,
ancillary-windows.txt, that is a replacement for the HP Clustered File System
Third-Party Licenses document provided with the 3.6.1 release. The file is installed in
the following folder: C:\Program Files\Hewlett-Packard\HP Clustered
File System\doc.
Update recommendation Critical
Operating systems
Microsoft Windows Server 2003 SP1 or SP2 Standard or Enterprise Edition, Microsoft
Windows Server 2003 R2 Standard or Enterprise Edition, Microsoft Windows Server
2003 R2 SP2 Standard or Enterprise Edition.
Fixes
HP Clustered File System 3.6.1 hotfix 1 resolves the following issues:
• Defect 23932. Filesystem corruption could generate a page fault that caused
the system to panic. Also, the psfscheck utility terminated early, during the
"Reinitializing Journal" phase, when it encountered corruption in a large file in
the process of being truncated.
• Defect 24203. When 8.3 SFNs were enabled with extended character support,
a CRC error occurred when the user attempted to create or change a filename
containing certain extended ASCII or unicode characters.
• Defect 24225. In some cases, the PSFS filesystem failed to grant privileged
access to files.
• Defect 25079. This fix is intended for Clustered Gateway Systems. Set ings for
the lanman server registry items were not correctly tuned for larger CIFS work
loads such that the McAfee virus scan software would see Event 2021 or Event
2022 alerts in its logs. The registry values are now more correctly tuned for
this type of work load.
• Defect 25285. An issue with SNMP trap event notification could corrupt packet
data.
• Defect 25286. Event notifications were sent for some internal events that were
not listed or selectable.
• Defect 25305. An issue with SNMP trap event notification caused HP SIM to
display variable bindings incorrectly.
HP StorageWorks Clustered File System for Windows product update 3.6.1h1
3


...

Эта инструкция также подходит к моделям:
Устройства обработки данных - HP DL380-SL Clustered Gateway (40.65 kb)
Устройства обработки данных - HP ProLiant DL380G5-WSS Storage Server Clustered Gateway (40.65 kb)
Устройства обработки данных - HP ProLiant DL380G5-WSS Storage Server Initial Cluster (40.65 kb)
Устройства обработки данных - HP 3PAR StoreServ File Controller v2 Storage (40.65 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории