Производитель: HP
Размер: 81.49 kb
Название файла:
|
К этому устройству также есть другие инструкции:
Фрагмент инструкции
3. Pull the blank straight out of the enclosure.
Verifying Partner Firmware Upgrade is
enabled
By default the storage system’s Partner Firmware Upgrade feature is
enabled, so when you upgrade a controller the system automatically
ensures that both controllers have the more recent version.
•
Log in to the command-line interface (CLI) and run the following
command to verify that Partner Firmware Upgrade is enabled.
show advanced-settings
If Partner Firmware Upgrade is disabled, enable it by running the
command:
set advanced-settings partner-firmware-upgrade
enabled
Verifying controller status
Once the controller completes initializing and is online:
• Verify that the heartbeat LED on the front of the enclosure is green.
Install controller(s)
• Verify that the OK LED on the back of the controller is green.
NOTE:
NOTE:
For clarity, only relevant details are shown in these il ustrations.
If the OK LED is blinking, the controller is still initializing.
1. Loosen the thumbscrews; press the latches downward.
2. Slide the controller into the enclosure as far as it will go (1).
Additional information
3. Press the latches upward to engage the controller (2); turn the
thumbscrews finger-tight.
See the MSA web site: ht p://www.hp.com/go/msa.
4. Connect cables according to a supported configuration. See the
user guide.
Upgrading an existing single controller
system to a dual control er
If you have an existing single controller system and you are adding a
second controller, the new controller automatical y begins to initialize
when it is installed. If the firmware versions differ between the two
control ers, Partner Firmware Upgrade feature brings the older firmware
to the later firmware level.
Page 2