К этому устройству также есть другие инструкции:
Фрагмент инструкции
Site requirements
HP StorageWorks 60 Modular
2. Secure the back end of the rails to the rack.
4
Power cords
The power cord should be approved for use in your country. The power
Select an installation site that meets the following requirements:
Smart Array Enclosure
IMPORTANT: Be sure that the scissor-type locking latches engage
Choosing a configuration
the rack fully when the pins extend through the holes marked with
cord must be rated for the product and for the voltage and current marked
• Space
• Temperature
the template.
on the electrical ratings label of the product. The voltage and current rating
Cable procedures vary, depending on the configuration. Choose one of the
• Power
• Rack
for the cord should be greater than the voltage and current rating marked
Setup Poster
following configurations.
on the product. In addition, the diameter of the wire must be a minimum of
• Grounding
• Airflow
Single-enclosure configuration
1.00 mm2 or 18 AWG, your maximum length may be up to 3.66 m (12 ft).
Detailed installation site requirements for this server are described on
the Documentation CD.
WARNING: To reduce the risk of electric shock or damage to
the equipment:
Rack planning resources
• Do not disable the power cord grounding plug. The grounding
plug is an important safety feature.
The rack resource kit ships with all HP branded or Compaq branded 9000,
10000, and H9 series racks. For more information on the content of each
• Plug the power cord into a grounded (earthed) electrical outlet
resource, refer to the rack resource kit documentation.
that is easily accessible at all times.
If you intend to deploy and configure multiple servers in a single rack,
refer to the white paper on high-density deployment at the HP website
• Unplug the power cord from the power supply to disconnect
http://www.hp.com/products/servers/platforms
power to the equipment.
Rack warnings
• Do not route the power cord where it can be walked on or
pinched by items placed against it. Pay particular attention to
the plug, electrical outlet, and the point where the cord extends
from the storage system.
WARNING: To reduce the risk of personal injury or damage to the
equipment, be sure that:
3. Slide the chassis into the rack.
To connect AC power cords:
• The leveling jacks are extended to the floor.
4. Use the thumbscrews on the front of the chassis to secure it to the rack.
1. Connect the power cords to the power supplies.
• The full weight of the rack rests on the leveling jacks.
5. Use the shipping bracket to secure the storage enclosure for shipping:
2. Connect the power cords to the AC power source.
• The stabilizing feet are attached to the rack if it is a
Item
Description
IMPORTANT: Use of the shipping bracket is required only when the
Important safety information
single-rack installation.
rack is shipped with the MSA60 installed.
1
MSA60
• The racks are coupled together in multiple-rack installations.
a. Loosen the thumbscrew on the shipping bracket.
2
SAS cable
6 Powering up the storage enclosure
• Only one component is extended at a time. A rack may become
b. Slide the shipping bracket forward until it engages the chassis.
3
Server
unstable if more than one component is extended for any reason.
c. Tighten the thumbscrew.
Observe the following guidelines before powering up the storage enclosure:
Læs dokumentet Vigtige sikkerhedsoplysninger på dokumentations-cd'en, før produktet installeres.
Cascading (1+1) configuration
• Always install all components of the storage enclosure.
WARNING: To reduce the risk of personal injury or equipment
If you are installing the storage enclosure into a telco rack, order the
damage when unloading a rack:
appropriate option kit at the RackSolutions website
• Install hard drives in the storage enclosure so the connected host controller
http://www.racksolutions.com/hp
can identify and configure them at power up.
• At least two people are needed to safely unload the rack from
the pallet. An empty 42U rack can weigh as much as 115 kg
To power up the storage enclosure:
Follow the storage enclosure-specific instructions on the website to install the
(253 lb), can stand more than 2.1 m (7 ft) tall, and may become
rack brackets.
1. Complete server hardware installation and cabling. Refer to the
unstable when being moved on its casters.
Prima dell'installazione, leggere sul CD le Informazioni importanti sulla sicurezza.
Use the following information when connecting peripheral cables and
server documentation.
• Never stand in front of the rack when it is rolling down the ramp
power cords to the storage enclosure.
2. Connect the SAS cables and power cords to the storage enclosure.
from the pallet. Always handle the rack from both sides.
3. Press the Power On/Standby button.
Wait and observe the system power LED and controller display.
Contents of the storage enclosure
When the storage enclosure powers up, the system power LED
Les "Viktig sikkerhetsinformasjon" på dokumentasjons-CDen før du installerer dette produktet.
shipping carton
illuminates solid green.
4. Power up the servers. Refer to the server documentation.
When unpacking the MSA60, locate the following items:
• MSA60
• Rack mounting hardware kit
7 Updating firmware
Tärkeisiin turvatietoihin" Documentation CD -levyllä ennen tuotteen asentamista.
• Power cords (2)
Läs dokumentet Viktig säkerhetsinformation på dokumentations-cd:n innan du installerar denna produkt.
• SAS cable
To update the firmware on the server, controller, hard drives, or enclosure
use Smart Components. These components are available on the Firmware
• Documentation kit
Item
Description
Maintenance CD. A more recent version of a particular component might be
1
MSA60 1*
available on the support page of the HP website
http://www.hp.com/support
1
2
MSA60 2*
Installing a storage enclosure into
3
SAS cable
After installing hardware and powering up the storage enclosure for the first
time, be sure to verify that the host controllers and drives have the latest
the rack
4
SAS cable
firmware. For firmware and software updates, refer to the HP website
Item
Description
5
Server
http://h18004.www1.hp.com/support/files/storage/us/index.html
To install the storage enclosure into the rack:
1
Power supply 1
* Only MSA60 enclosures can be cascaded. Do not configure with other
To receive proactive email support alerts such as customer advisories,
1. Secure the front end of the rails to the rack.
2
Fan module 1
types of storage enclosures.
updates on drivers, software, firmware, and customer replaceable compo-
nents, sign up for HP Subscriber's Choice. Go to HP Subscriber's Choice on
IMPORTANT: Do not remove the pins from the ends of the rack rails
3
Dual 7-segment display board (for box ID numbering)
Additional supported configurations:
the HP website
unless you are converting the rails for use in round-hole racks. These
4
SAS in connector
• 1+2 configuration for a total of three cascading enclosures.
load-bearing pins are designed to fit through the holes without
http://www.hp.com/go/myadvisory
• 1+3 configuration for a total of four cascading enclosures.
being removed.
5
SAS out connector
and then select the appropriate product.
6
I/O module bay
IMPORTANT: Be sure that the scissor-type locking latches engage
7
For future use
the rack fully when the pins extend through the holes marked with
8
Fan module 2
5 Cabling the storage enclosure
the template.
9
Power supply 2
Additional information
After installing the storage enclosure in a rack, connect the SAS cables and
NOTE: Identify the left (L) and right (R) rack rails by markings
power cords to the rear panel.
For more information about this product, refer to the HP StorageWorks 60
stamped into the sheet metal.
Modular Smart Array Enclosure User Guide on the Documentation CD.
2
Supported cables
For definitions of the acronyms used in this document, refer to "Acronyms
Installing hardware options
A 0.5-m (20-in) SAS cable ships standard with the storage enclosure.
and abbreviations" on the Documentation CD.
To acquire different lengths, contact the nearest authorized HP reseller.
Install any hardware options before initializing the storage enclosure.
Audience assumptions
For options installation information, refer to the option documentation.
HP recommends using the shortest cables possible. However the
This document is for the person who installs, administers, and troubleshoots servers and
For storage enclosure-specific information, refer to the storage enclosure
maximum supported cable length that can be used between SAS ports
storage systems. HP assumes you are qualified in the servicing of computer equipment
user guide.
is 6-m (19.68-ft).
and trained in recognizing hazards in products with hazardous energy levels.
For a complete list of supported cables, see the QuickSpecs on the
HP website
Regulatory compliance notices
3
http://www.hp.com
Installing servers
Regulatory compliance identification numbers
SAS cabling guidelines
For the purpose of regulatory compliance certifications and identification, this
Install the servers in the rack directly above the storage enclosure. Refer to
Observe the following guidelines:
product has been assigned a unique series number. The series number can be
the server documentation.
found on the product nameplate label, along with all required approval markings
• Only use supported SAS cables with 3-Gb connectors.
and information. When requesting compliance information for this product, always
NOTE: When installing servers, HP recommends installing all
• Always be sure that the servers attached to the storage enclosure are
refer to this series number. The series number should not be confused with the
marketing name or model number of the product.
storage enclosures at the bottom of the rack. To optimize
powered down and power cords are disconnected before connecting
cabling access, avoid interleaving the storage enclosure and
SAS cables.
Legal notices
server products.
© Copyright 2006 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only
warranties for HP products and services are set forth in the express warranty
statements accompanying such products and services. Nothing herein should be
construed as constituting an additional warranty. HP shall not be liable for
technical or editorial errors or omissions contained herein.
November 2006 (Second edition)
Part number 405959-402
Printed in the US
405959- 402
...Эта инструкция также подходит к моделям:
Устройства обработки данных - HP MSA60 Dual Domain (12) 1TB 3.5-inch DP SAS MDL HDD 12TB Bundle (1.68 mb)
Устройства обработки данных - HP MSA60 Dual Domain (12) 450GB 3.5-inch DP SAS HDD 5.4TB Bundle (1.68 mb)
Устройства обработки данных - HP MSA70 Array (1.68 mb)
Устройства обработки данных - HP MSA70 Dual Domain (25) 300GB 2.5-inch DP SAS HDD 7.5TB Bundle (1.68 mb)