Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации HP, модель Disk System 2300 Deskside Disk Integration

Производитель: HP
Размер: 93.57 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию


Фрагмент инструкции


DS2300 / DS2405
Figure 2: Disk Drive LEDs

B
A

A
B



Note The green Activity LED (A in Figure 2) should be on while the disk spins up and then turn off. The
green Activity LED (A) will blink with I/O activity to the disk. An amber light (B in Figure 2) that is on
briefly when a component first comes on is normal. If this light stays on more than a couple of seconds, a
fault has been detected. See Table 2 for a full list of disk LED behaviors.


If you observe different results, further Troubleshooting may need to be carried out. (See Chapter 4 of
the
HP StorageWorks Disk System 2300 User’s Guide or HP StorageWorks Disk System 2405 User’s Guide
for troubleshooting procedures.)

Table 2: DS2300 / DS2405 Disk Drive LEDs Status Indications

A
B


Disk
Disk Fault

Indication
Activity
(Amber**)


(Green*)

ON
OFF
Installed and spinning up. If the LED is still on 3 minutes

after power is engaged, the disk may be faulty.


Flashing
OFF
Disk drive self-test in progress or there is input/output

activity to the disk.

OFF
ON
Disk drive fault (Controlled by host software).


ON/OFF
Flashing
Host is identifying the disk drive. (Controlled by the host

software).


OFF
OFF
Disk drive not installed or not operating.

*Controlled by the disk drive.
**Controlled by the host software.


...

Эта инструкция также подходит к моделям:
Устройства обработки данных - Disk System 2300 Factory Rackable Disk Integration (93.57 kb)
Устройства обработки данных - Disk System 2300 Factory Rackable SEP Integration (93.57 kb)
Устройства обработки данных - Disk System 2300 Field Rackable Disk Integration (93.57 kb)
Устройства обработки данных - HP StorageWorks Disk System 2405 (fctry rcked) (93.57 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории