Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Kettler, модель 700

Производитель: Kettler
Размер: 1.65 mb
Название файла: 5aabf1c8-e37c-43f1-9953-28253754e940.pdf

Язык инструкции:enfrdenl

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


Prior to and during training the pedalling resistance can be selected in 5-Watt steps from 25 to 400 Watt in all programs except the training controlled by pulse frequency. If you press the keys for entering training data (15/16) for a short time, the respective value is increased or reduced in simple steps. If the key is pressed down for more than 2 seconds, the setting intervals rise (refer to table). The graphic display (5) will be adapted automatically. Pressing the plus and minus pushbottons simultaneously will set the pedalling resistance to 25 Watt.The adjustment of the graphic display will be carried out in 25-Watt steps. You also have the possibility to adopt the preset training pulse in the nine stored programs. You can do this by changing into the respective training program after actuating the preset pulse in "count-down" mode via program key (17) without starting training. Training without preset training data (manual mode) When activating the computer by pedalling, after pressing the ”delete” key (13) or after pressing the program key (17) in pulse program, the display will be in manual mode (default format). All values with the exception of the current pulse value and the performance display (4) will be set to zero. Now, simply start training. The values will be counted upwards with the exception of the values for watt (4), pedal rotations (2) and velocity (8) (current values). Velocity (8) and distance covered (9) are displayed alternately every 4 seconds. In manual display mode, the bar graph (5) will display the current performance profile of the person undergoing training. During training, the current performance will be displayed in the left bar. It is 25 watt per segment. In intervals of one minute each, the active bar (left) remains on the final value and then moves to the next bar on the right side. In the course of training, the display will "wander" from the left to the right. The new current value is always displayed in the left bar. In manual mode, the performance will be registered till the training is ended. When the training unit is completed or interrupted or if the pedal rotations/ min. remain below the preset value by 20 rotations, the computer will display the following data: Time (7), energy consumption (3) and distance covered (9). When training is continued within four minutes without changing the program mode, the counting of time (7), energy consumption (3) and distance covered (9) will be continued. After an interruption of training of more than four minutes the values will get lost and the computer will switch to standby mode. Training with preset training data (manual mode ”count-down”) After switching on the computer and pressing the program key (17) once, the display will be in manual mode ”count-down”. Merely the time (7) and the display mode (6) ”manual” will be displayed. The training time is preset with the up and down keys (15/16). Pressing the up and down keys simultaneously will delete the preset value. When the desired value has been reached or if no time value is to be programmed, press the ”set” key (14) for accepting the value and for switching further to the kilojoule display (3). After setting the kilojoules as described before, you can also preset the distance covered (9) as well as the training pulse (10). Pressing the ”set” key (14) again will switch the display back to "COUNT-DOWN". With the exception of previously programmed values, all values will be set to 1. Symbol for exceeding or falling below the admissible pedal rotations 2. Display for pedal rotations (20 - 150 rpm) 3. Display for energy consumption (0 - 1999 kilojoule [kJ];1 kcal.4,2 kJ) 4. Display for performance in 25 – 400 watt 5. Graphical representation of load profile 25 – 250 watt 6. Current display mode 7. Display for timekeeping (0:00 - 99:59) 8. Display for velocity (0 - 53 km/h) 9. Display for distance covered (0 - 99.9 km) 10. Display for current pulse beat (40 - 199 beats/min.) 11. Symbol for pulse beat 12. Symbol for exceeding (HI) or falling below (LO) the given pulse 13. Key for deleting the training data 14. Key for presetting the training data 15. Key for entering the training data (increase the number) 16. Key for entering the training data (reduce the number) 17. Key for program selection 18. Key for recovery pulse 19. Connection for pulse measuring Rear side of the display: Interface for KETTLER VIDEO SYSTEM and software ERGO KONZEPT (accessories) Please, contact your specialised dealer. Preprogrammed measuring values In case of a failure of the measuring values programmed in our company the letters ”CAL” appear in the graphical display (5) when the computer is switched on. Then the computer has to be returned to KETTLER for a new calibration. Description and operating instructions for computer Display after connection to power supply As soon as the computer has been connected to the power supply, all segments of the display will be displayed for 4 seconds. This shor...

Эта инструкция также подходит к моделям:
Тренажеры - 7987-500 (1.65 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории