Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Invacare, модель Electric Portable Patient Lift RPA600-1E

Производитель: Invacare
Размер: 1.09 mb
Название файла: 1078988.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


WARNING The legs of the lift must be in the maximum open position and the shifter handle locked in place for optimum stability and safety. If it is necessary to close the legs of the lift to maneuver the lift under a bed, close the legs of the lift only as long as it takes to position the lift over the patient and lift the patient off the surface of the bed. When the legs of the lift are no longer under the bed, return the legs of the lift to the maximum open position and lock the shifter handle immediately. 1. With the legs of the base open and locked, use the steering handle to push the patient lift into position. 2. Lower the patient lift for easy attachment of the sling. FIGURE 4.1 Positioning the Lift Part No 1078988 19 Electric Portable Patient Lift - RPA6001E SECTION 4—LIFTING THE PATIENT Attaching a Sling to the Swivel Bar WARNING The maximum weight capacity of the RPA600-1E patient lift is 600 lbs. DO NOT exceed the maximum weight capacity of the patient lift otherwise, injury or damage may occur. Before using the sling, read and understand all operating instructions provided in the sling owner’s manual. Bleached, torn, cut, frayed or broken slings are unsafe and could result in injury. Discard IMMEDIATELY. DO NOT alter slings in any way. Invacare slings are made specifically for use with Invacare Patient Lifts. For the safety of the patient, DO NOT use slings and patient lifts of different manufacturers. 1. Place the straps of the sling over hooks of the swivel bar. 2. Match the corresponding colors on each side of the sling for an even lift of the patient. NOTE: The Invacare Swivel Bars have three hookup points per side. WARNING The patient lift MUST be moved with the push handles on the mast assembly - otherwise, injury or damage may occur. DO NOT move the patient outside the center of gravity achieved after the patient is suspended in the sling and the patient lift adjusts. 3. Lift the patient. Refer to Lifting/Moving the Patient. Lifting/Moving the Patient WARNING DO NOT lock the rear casters of the lift when lifting an individual. Locking the rear casters could cause the lift to tip and endanger the patient and assistants. DO NOT move the patient if the sling is not properly connected to the hooks of the swivel bar. When the sling is elevated a few inches off the surface of the bed and before moving the patient, check again to make sure that the sling is properly connected to the hooks of the swivel bar. If any attachments are NOT properly in place, lower the patient back onto the stationary surface and correct this problem - otherwise, injury or damage may occur. Adjustments for safety and comfort should be made before moving the patient. Patient's arms should be inside of the straps. DO NOT use slings and patient lifts of different manufacturers. Invacare slings are made specifically for use with Invacare patient lifts. Injury or damage may occur. Electric Portable Patient Lift - RPA6001E 20 Part No 1078988 SECTION 4—LIFTING THE PATIENT NOTE: For this procedure, refer to FIGURE 4.2. NOTE: Whenthepatient isliftedfromthebedorthefloor (with the patient’s headsupported bythesling and/or an assistant), he/she will be raised to a sitting position (Detail “A” of FIGURE 4.2). 1. Press the up button on the hand control to raise the patient high enough to clear the bed surface. The patient’s full body weight will be supported by the lift. NOTE: The boom will stay in this position until the up or down buttons are pushed on the hand control. 2. Place the patient’s arms inside of the sling. 3. When the patient is clear of the bed surface, swing their feet off the bed (Detail “B” of FIGURE 4.2). 4. Using the handle, move the patient lift away from the bed. 5. Turn the patient so that he/she faces assistant operating the patient lift (Detail “C” of FIGURE 4.2). 6. Press the down button to lower the patient so that his/her feet rest on the base of the lift, straddling the mast. NOTE: The lower center of gravity provides stability making the patient feel more secure and the lift easier to move. 7. Push the lift with both hands firmly on the steering handle. DETAIL “A” - LIFTING THE PATIENT DETAIL “B” - MOVING THE PATIENT DETAIL “C” - MOVING THE PATIENT LIFT AWAY FROM THE BED FIGURE 4.2 Lifting/Moving the Patient Part No 1078988 21 Electric Portable Patient Lift - RPA6001E SECTION 5—TRANSFERRING THE PATIENT SECTION 5—TRANSFERRING THE PATIENT Introduction WARNING DO NOT attempt any transfer of a patient without approval of the patient's physician, nurse, or medical assistant. DO NOT move the patient if the sling is not properly connected to the hooks of the swivel bar. When the sling is a few inches off the surface of the bed and before moving the patient, check to make sure that the sling is properly connected to the hooks of the swivel bar. If any attachments are NOT properly in place, lower the patient back onto the stationary surface and correct this problem - otherwise, injury or damage may occur. A...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории