Производитель: Desa Tech
Размер: 1.04 mb
Название файла:
|
Фрагмент инструкции
Set one-piece log on heater base as shown in Figure 14. Make sure middle section at bottom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 14). 2. Fasten back panel to stove with four (4) bolts and washers removed in step 4 of Unpacking, page 7. Make sure product identification label is located on the outside lower left-hand corner. 3. Place freestanding stove in desired position being careful not to damage gas connections. Be sure to maintain clearances to combustibles and wall clearances as outlined on page 8. Figure 14 - Installing One-Piece Stove Log Set One-Piece Log Set Heater Base "U" Shaped Cutout in Chassis Burner Middle Section at Bottom of Log Set Burner Porting Areas (double slotted rectangular openings Figure 15 - Top View of One-Piece Log Set on Gas Log Heater Safety Pilot Location One-Piece Log Set OPERATING HEATE R FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor.s phone. Follow the gas supplier.s instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don.t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified servicetechniciantoinspecttheapplianceand to replace any part of the control system and any gas control which has been under water. LIGHTING INSTRUCTIONS NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orangeflamewillalsobepresent. Open a window to vent smell. This will only last a few hours. 1. STOP! Read the safety information, abovc. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don.t smell gas, go to the next step. 5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 16). Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. 6. Withcontrolknobpressedin,pressandrelease ignitorbutton.This will light pilot.Thepilotis attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 14. 7. Keep control knob pressed in for 30 seconds after lighting pilot.After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO. CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. Ignitor Button Control Knob Figure 16 - Control Knob and Ignitor Button Location Thermocouple Pilot Burner Figure 17 - Pilot 111487-01D OPERATING HEATER Note: The correct pilot flame on natural gas units will have a slight curve, but flame should be blue Continued TO TURN OFF GAS TO APPLIANCE and have no yellow or orange color. Pilot Shutting Off Heater Burner Turn control knob clockwise to the OFF position. Thermocouple Figure 18 - Correct Pilot Flame Pattern Shutting Off Burners Only (pilot stays lit) (Propane/LP Shown) Turn control knob clockwise to the PILOT position. Pilot Burner Thermocouple THERMOSTAT CONTROL OPERATION The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower se...
Эта инструкция также подходит к моделям:Тренажеры - CSBNT (1.04 mb)
Тренажеры - CSBPT (1.04 mb)
Тренажеры - CSPBNT (1.04 mb)
Тренажеры - CSPBPT (1.04 mb)